Assembly Instructions - Health O Meter PROPLUS 2650KGWA User Instructions

Digital wheelchair platform scale
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
2650KGWA ASSEMBLY INSTRUCTIONS
Before Assembly (2650KGWA):
®
The ProPlus
2650KGWA Wheelchair Patient Digital Platform Scale is shipped in one carton. Carefully inspect
the carton for shipping damage before unpacking. If damage is found, contact Customer Service. The following
information details what you will find inside the main carton.
Remove each assembly from the carton and unwrap packing material carefully, to prevent scratching the unit's
parts. Set the carton aside, for storage. To avoid damaging the scale parts when unpacking it, do not use a box
cutter, knife, scissors or any sharp object to open the protective inner packaging.
Parts List:
(1) Base / Platform Assembly (with 2 ramps, handle, wheels attached)
(1) User information
(1) Box Containing:
(1) Display Assembly with attached Load Cell Connector Cable
(1) Small Box Containing:
(1) Power Adapter
(4) Feet
Assembling a 2650KGWA Scale:
This scale takes only minor assembly.
1. Place scale base on a flat, level, dry floor—place upside down carefully.
2. Thread the 4 feet into the underside of the base. Each foot should be completely hand tightened
and then backed out 1-½ full turns. This allows for proper load cell operation for accuracy of the
scale.
3. Carefully tilt the scale back to an upright position on the floor with care to watch the ramp—it may
flip down when the scale is tipped back. DO NOT DROP THE SCALE. Adjust the feet, to level the
scale. Be certain that the feet are NOT completely tightened into the base (see Step 2, above).
4. Open the scale to operational position.
5. Connect the load cell cable connector to the load cell port on the scale base.
6. Connect the power adapter cord to the power port in the display, if the adapter will be used. The
cord will be outside of the display, as shown in Figure 1. It is optional to run the cord through the
channel in the back of the display, if you prefer. To accomplish this, remove the 4 screws (A) in the
back with a Phillips screwdriver, remove the cover, run the power cord (B) through the channel, and
then replace the cover, secure it with the 4 screws and tighten.
7. The scale is now assembled. Plug the scale adapter into a power source and / or insert batteries—
see the batteries section / Figure 2 for more information regarding batteries.
Figure 1
5

Advertisement

Table of Contents
loading

Table of Contents