6. In Control Panel, double-click the Modems icon.
7. If prompted, enter the necessary dialing information for your location. When the
Modems Properties dialog box displays, click the Diagnostics tab. A list of ports
and devices appears.
8. Highlight the COM port associated with the Multi-Tech MT5634ZPX. Click More
Info. Clicking More Info causes Windows to send commands to and receive
responses from the modem. The system also displays information about the
modem's COM port.
9. Write down the modem's port, interrupt, address, and highest speed. You will need
this information to configure legacy (nonWindows) communications software you
install.
Port: COM ______ Interrupt:_______ Address:_______ Speed: _______
10. Click the General tab. Select Multi-Tech Systems MT5634ZPX and click Properties
to review the modem's default communications settings. Do not change any settings
unless you have special requirements.
11. From General tab, click Dialing Propertie s and review your dialing settings. If you
are required to dial 9 to get an outside line, type 9 in the local and long distance
boxes. If you have call waiting service, disable it to prevent it from interrupting a data
or fax transmission. When finished, click OK to exit the Modems Properties dialog
box.
The Four Position DIP Switch
DIP#
1
2&3
4
* Factory Default Setting
After you have selected the desired COM Port via the 4-position DIP-Switch, you must
assign an IRQ address by placing the IRQ jumper in the correct position. The figure
which follows shows the jumper and DIP-switch in the default position for PnP.
Select the IRQ for your COM port by moving the supplied shorting plug, or jumper, to the
two pins below the desired IRQ number. Select an address and an IRQ that does not
conflict with others in your computer. Supported IRQ values for the MT5634ZPX are
3,4,5,7,9,10,11,12 and 15.
Note: The jumper must be in the default position (IRQ3) for PnP.
Multi-Tech Systems, Inc. MT5634ZPX User Guide
Position
Effect
Open (Up)*
Selects Plug and Play
Closed (Down)
Selects Non-Plug and Play
2 Open
3 Open
2 Closed
Base Address = 2F8 COM2
3 Open
2 Open
Base Address = 3E8 COM3
3 Closed
2 Closed*
Base Address = 2E8 COM4
3 Closed*
Reserved for future use
Chapter - 2 Hardware Installation
Base Address = 3F8 COM1
15