Case2: Silencing the alarm from the digital depth indicator FE-720
When the main display unit FE-701 activates an alarm, it can be deactivated at the FE-701 itself
and also, it can be deactivated from the digital depth indicator FE-720. To do this, connect as
follows.
Connection
DISTRIBUTION BOX
FE-702
TB1
1
6
7
TD1-A
TD1-B
8
RD1-A
9
RD1-B
10
Ship's mains
+
24 VDC
-
Note: In this case, a positioning device can not be connected.
FE-720 setting
In the menu of the FE-720, ALARM should be set to ON. If an alarm activates, press any key on
the FE-720, then the alarm will be deactivated at the FE-701 and FE-720.
TERMINAL BOX
DS-802(option)
TTYCYS-4
1
2
3
4
5
6
7
8
DIM CONTROL
LANGUAGE
CONTRAST
ALARM
TEST
MJ-A7SPF0009-020C
< 1 < TD-A
WHITE
< 2 < TD-B
BLUE
< 3 < RD-A
YELLOW
< 4 < RD-B
GREEN
< 5 < 24V
RED
< 6 < 0V
BLACK
< 7 < GND
MENU
PANEL ONLY
ENGLISH
ON
18
DIGITAL DEPTH INDICATOR
FE-720
IN/OUT