8. ALARM CYCLE

Any irregularity being detected:
by the peripheral protection circuit (e.g. the opening of a protected storage compartment or case)
-
-
by the movement sensor (e.g. an attempt to drag the motorcycle away)
-
by the ignition lock tamper protection circuit (e.g. an attempt to force the lock)
generates a 30-sec. alarm cycle.
The alarm condition is signalled by the 114dB piezoelectric siren that is integrated in the device (sound
warning) as well as by the flashing of the turn indicators (visual warning).
After that the device automatically returns to the set condition.
During the alarm condition pressing the remote control button n. 1 once will simply silence the siren and stop
the indicators, leaving the system armed and ready to detect further irregularities. In order to disarm the
system it is necessary to press the push-button twice.
In order to minimise environmental disturbance, the alarm cycles in an activation period are limited to a
maximum of 10/sensor trigger input.

8.1. Reduction of audible alarm power

The sound alarm can be weakened when the motorcycle is parked in areas where unnecessary noise has to
be avoided. When arming, keep push-button n. 1 of the transmitter pressed for about 7 seconds. Upon arming,
keep push-button n. 1 pressed for about 7 seconds. The reduction of the sound power is confirmed by two
deep short audible signals. This setting is valid for one arming period only.