2-2. When the protection function worked due to
abnormal DC output.
D C P R T : x x x H
Cause: DC output of the power amplifier is abnormal.
Supplementary information: The protection function
worked due to a DC voltage appearing at the speaker
terminal. A cause could be a defect in the amplifier.
Turning on the power without correcting the abnormality
will cause the protection function to work in 5 seconds
and the power supply will be shut off.
2-3. When the protection function worked due to
abnormal voltage in the power supply section.
P S P R T : x x x L
Cause: The voltage in the power supply section is
abnormal.
Supplementary information: The protection function
worked due to a defect or overload in the power supply.
Turning on the power without correcting the abnormality
will cause the protection function to work in 1 seconds
and the power supply will be shut off.
Notes:
Applying the power to this unit without correcting
the abnormality can be dangerous and cause
additional circuit damage. To avoid this, if "PS"
and "DC" protection function works 3 times
consecutively, the power will not turn on even
when the " " (Power) key is pressed. In order
to turn on the power again, start up the self-
diagnostic function.
The output transistors in each amplifier channel
should be checked for damage before applying
power to this unit.
Amplifier current should be monitored by
measuring DC voltage across the emitter resistors
for each channel.
32
H: Displayed when the voltage is HIGHER than upper limit
電圧が上限値より高い場合に表示されます
L: Displayed when the voltage is LOWER than lower limit
電圧が下限値より低い場合に表示されます
xxx: A/D conversion value of voltage at the moment when the protection function worked
(Reference voltage: 3.3 V=255)
プロテクションが働いた瞬間の電圧の A/D 変換値
(基準電圧:3.3 V=255)
H: Displayed when the voltage is HIGHER than upper limit
電圧が上限値より高い場合に表示されます
L: Displayed when the voltage is LOWER than lower limit
電圧が下限値より低い場合に表示されます
xxx: A/D conversion value of voltage at the moment when the protection function worked
(Reference voltage: 3.3 V=255)
プロテクションが働いた瞬間の電圧の A/D 変換値
(基準電圧:3.3 V=255)
2-2. DC 出力異常によりプロテクションが働いた場合
原因: パワーアンプの DC 出力が異常。
補足: アンプの故障でスピーカー端子に直流電圧が掛か
るなどが原因で、プロテクションが働いたことを
示します。
異常状態のまま電源を入れると、5 秒後にプロテクション
が働き、電源が切れます。
2-3. 電源部の電圧異常によりプロテクションが働い
た場合
原因: 電源部の電圧が異常。
補足: 電源電圧による原因で、プロテクションが働いた
ことを示します。
異常状態のまま電源を入れると、1 秒後にプロテクション
が働き、電源が切れます。
注意:
・ 異常状態のまま本機の電源を入れると、危険な状態
になり、さらに回路が損傷を受ける原因になります。
それを避けるために、 「DC」 、 「PS」プロテクション
が連続して 3 回目働いた場合、それ以降
キーを押しても電源が入らなくなります。再度電源
を入れる場合、ダイアグを起動してください。
・ 本機の電源をいれる前に、各パワーアンプの出力ト
ランジスタに損傷がないかチェックしてください。
・ パワーアンプの電流は、各チャンネルのエミッター
の抵抗器間 DC 電圧を測定することによりモニター
してください。