Table of Contents

Advertisement

Care should be taken to maintain suffi cient clearance for
the vent installation. A horizontal vent installation requires
a minimum height of 45" using fl exible vent pipe, to the
underside of the enclosure top including the 2" clearance
to combustibles
4.3

COUNTER TOP / BAR INSTALLATION

When fi nishing the appliance, combustible material
may rest directly on the top extension.
NOTE: Maximum weight tolerance is 400 lbs, pro-
vided that it is evenly distributed across the top
extensions of the appliance.
In order to achieve a counter top or bar type appear-
ance with the minimum height allowed, framing must
be non-combustible and may be done with metal
studding attached to the top extension sides or the
upper frame of the appliance.
* The top extension may be removed if non-combus-
tible framing is faced with a non-combustible mate-
rial placed fl ush with the front face of the appliance
and extending from the top of the appliance. (Ex-
ample: cement board - not supplied). Combustible
counter / bar tops must maintain a minimum of 38"
from the base of the appliance to the underside of
the top.
NOTE: Wolf Steel trim and/or surround kits will
not totally cover the top extension of the appli-
ance. In order to obtain a smooth transition from
the trim / surround to the wall, it is recommended
that the top extension be removed and the appli-
ance be installed following the above procedure.
2" CLEARANCE TO COMBUSTIBLES
20" MINIMUM INSIDE DIMENSION
7"
45"
MINIMUM
19
7"
W415-0811 / D / 08.16.12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bgd40-p

Table of Contents