Diagram 5.4 - Power Control Module Connector Numbering
4.
If the incline moves normally skip to step 7.
5.
If the display indicates that the incline should be moving and the incline motor does not
move and A.C. line voltage is present, skip to step 12.
6.
If the display indicates that the incline should be moving and the incline motor does not
move and A.C. line voltage is not present, replace the power control module.
7.
With the incline above 0%, connect an A.C. voltmeter between terminals 1 & 5 of the
INCLINE connector. See Diagrams 5.3 and 5.4. Set the treadmill in the manual program and
press the INCLINE
or 240 Vac). Note that the A.C. line voltage reading will only be present before an error
condition is displayed.
8.
If the incline moves normally skip to step 11.
9.
If the display indicates that the incline should be moving and the incline motor does not
move and A.C. line voltage is present, skip to step 12.
10. If the display indicates that the incline should be moving and the incline motor does not
move and A.C. line voltage is not present, replace the power control module.
11. If the incline is moving normally in both directions, there is either is not an incline problem or
the problem is intermittent. Intermittent problems are often caused by poor connections or
wiring problems.