Hot-Swap Fan - HP HPE ProLiant DL120 Gen9 Maintenance And Service Manual

Hide thumbs Also See for HPE ProLiant DL120 Gen9:
Table of Contents

Advertisement

CAUTION: To prevent improper cooling and thermal damage, do not operate the server
unless all bays are populated with either a component or a blank.
To replace the component, reverse the removal procedure.

Hot-swap fan

WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION: To prevent damage to electrical components, properly ground the server before
beginning any installation procedure. Improper grounding can cause ESD.
To remove the component:
Power down the server (on page 30).
1.
Remove all power:
2.
Disconnect each power cord from the power source.
a.
Disconnect each power cord from the server.
b.
Do one of the following:
3.
Extend the server from the rack (on page 30).
o
Remove the server from the rack (on page 33).
o
Remove the access panel
4.
Remove the air baffle (on page 34).
5.
Disconnect the fan cable from the system board and remove the fan.
6.
CAUTION: The fan does not have a fan guard. Special attention is needed when removing or
installing the fan to prevent finger injury.
To replace the component, reverse the removal procedure.
("Access
panel" on page 40).
Removal and replacement procedures 52