Commissioning/service reports
Control parameter report
Parameter
Heating water buffer cylinder
Enable buffer cylinder/low loss header
Temp. in operating status fixed value for
buffer cyl
Hysteresis temperature heating buffer
cylinder
Max. temperature buffer cylinder
Temp. limit op. status fixed value for buf-
fer cylinder
Heating circuit 1
Standard room temperature
Reduced room temperature
Remote control
Heating curve level
Heating curve slope
Influence room temperature hook-up
Room temperature hook-up
Max. flow temperature heating circuit
Room temperature in party mode
Heating circuit 2
Standard room temperature
Reduced room temperature
Remote control
Heating curve level
Heating curve slope
Influence room temperature hook-up
Room temperature hook-up
Max. flow temperature heating circuit
Room temperature in party mode
Cooling
Cooling function
Cooling circuit
Set room temperature separate cooling
circuit
Min. flow temperature cooling
Influence room temperature hook-up
cooling circuit
Cooling curve level
124
(cont.)
Code
Delivered condi-
tion
7200
0
7202
500 (≙ 50 °C)
7203
50 (≙ 5 K)
7204
600 (≙ 60 °C)
7208
100 (≙ 10 °C)
2000
200 (≙ 20 °C)
2001
160 (≙ 16 °C)
2003
0
2006
0 (≙ 0 K)
2007
6 (≙ 0.6)
200A
10
200B
3
200E
400 (≙ 40 °C)
2022
200 (≙ 20 °C)
3000
200 (≙ 20 °C)
3001
200 (≙ 20 °C)
3003
0
3006
0 (≙ 0 K)
3007
6 (≙ 0.6)
300A
10
300B
3
300E
400 (≙ 40 °C)
3022
160 (≙ 16 °C)
7100
0
7101
1
7102
200 (≙ 20 °C)
7103
100 (≙ 10 °C)
7104
0
7110
0 (≙ 0 K)
Commis-
sioning

Hide quick links:

Advertisement

Table of Contents
loading