Using
Your Cooktop
Operating
During Power Failure
If conditions change, follow the procedures outlined below
to adjust the Lo setting.
Hold a lighted match to the desired surface burner near the
burner ports. Push down and slowly turn the control knob
L Light burner and set control knob for low flame.
counterclockwise to the Hi setting.
2. Remove control knob from valve stem.
CAUTION: Never use a
NOTE: Do not leave the cooktop unattended when cook-
metal blade to pry knob
_ srO_CREASE
FLAME
ing during a power failure_ The automatic
re-ignition I
off.
feature will not operate during a power failure;
I
3. Insert aslender, thin-blade
I
screwdriver into the recess
at center of valve stem
Lo Flame Adjustment
andengagebladewithslot
in adjusting screw.
This appliance has been shipped from the factory with Lo
4. Turn center stem adjusting screw slightly to set flame size.
and Med flame settings adjusted for use with natural gas and
Note: Turn clockwise to reduce or counter-clockwise
to
average installations,
increase flame size.
5. Replace control knob when adjustment is completed.
There is a wide variety of conditions caused by altitude and
gas mixtures controlled by utility companies which will vary
Proper adjustment will produce a stable, steady blue flame of
and affect the gas flame and performance.
Adjustments
minimum size. The final adjustment should be checked by
should be made at time of installation,
turning
knob from Hi to Lo several
times without
extinguishing the flame.