Yamaha ACD1 Service Manual page 70

Amplifier control device
Hide thumbs Also See for ACD1:
Table of Contents

Advertisement

ACD1
c) Writing Boot/Program/Component
1.
Connection to PC
Connect the LAN terminal of the PC and the NETWORK terminal of the ACD1 with a LAN straight cable.
2.
Activating the ACD1
Turn on the power while holding down the following three keys on the ACD1 panel for fi ve seconds or more. (IP static mode)
[ ▲ INC/YES] + [ ▼ DEC/NO] + [NEXT]
The following screen will be shown on the LCD of the ACD1 when the IP static mode is started.
3.
Activating the software for writing component
Double click on the icon "sync2.exe" of C:¥ACD1¥Tool¥group¥.
4.
Check of setup
Check the following items.
Check if the [Confi guration fi le:] is set as follows. (Refer to "Setup/execution screen")
C:¥ACD1¥Data¥ACD1_update_list.dat
Component data writing will follow if all the parameters are correct.
5.
Writing of data and confi rmation of writing
• Click on the [Execute] button.
• Writing of only the necessary fi les will be conducted.
• Version is checked automatically when data is written from the fi rmware. (It is not necessary to click the [Confi rm] button.)
• If "V*.** or R*.**" is shown for the group version, the writing is fi nished successfully. Check that the version is identical to the
group version.
• Time necessary for writing depends on the version before writing and the version of data to be written.
• The "V*.** or R*.**" shows the group version, as "V1.10" in the fi gure. If "Error!!" is shown, it indicates that the boot/program/
component data is not written successfully. Write the data again.
6.
After writing data
Restarting will not take place automatically after writing data unlike boot/program updating. Turn off the power manually and then
restart if you want to start in the normal mode.
70