Yamaha ACD1 Service Manual page 66

Amplifier control device
Hide thumbs Also See for ACD1:
Table of Contents

Advertisement

ACD1
b) Writing component
1.
Connection to PC
Connect the LAN terminal of the PC and the NETWORK terminal of the ACD1 with a LAN straight cable.
2.
Activating the ACD1
Turn on the power while holding down the following three keys on the ACD1 panel for fi ve seconds or more. (IP static mode)
[ ▲ INC/YES] + [ ▼ DEC/NO] + [NEXT]
The following screen will be shown on the LCD of the ACD1 when the IP static mode is started.
3.
Activating the software for writing component
Double click on the icon "sync2.exe" of C:¥ACD1¥Tool¥sync¥.
4.
Check of setup
Check the following items.
Check if the [Confi guration fi le:] is set as follows. (Refer to "Setup/execution screen")
C:¥ACD1¥Data¥ACD1_cpt_list.dat
Component data writing will follow if all the parameters are correct.
5.
Writing component data
Click on the [Execute] button.
Writing of only the necessary fi les will be conducted.
The writing is fi nished when [Update was completed.] is displayed. (Refer to "Example of Writing Completion Screen")
6.
After writing component data
Restarting will not take place automatically after writing component data unlike boot/program updating. Turn off the power
manually and then restart if you want to start in the normal mode.
66
YAMAHA ACD1
000:
[Example of the ACD1 LCD display]
[Setup/execution screen]

Advertisement

Table of Contents
loading

Table of Contents