Troubleshooting
Fault codes
(cont.)
Dis-
Const.
played
fault
code
98
X
99
X
9A
X
9b
X
9C
X
9E
X
9F
X
A6
X
A7
94
Weath.-
System char-
comp.
acteristics
X
Control mode
X
Control mode
X
No DHW heat-
ing
X
Control mode
X
No DHW heat-
ing
X
Control mode
X
Control mode
X
Control mode
X
Control mode
as per deliv-
ered condition
Cause
Measures
Lead break,
Check sensor /
temperature
on solar control
sensor /
module.
Lead break,
Check sensor aÖ
temperature
on solar control
sensor aÖ
module.
Lead break,
Check temperature
collector tem-
sensor & on solar
perature sen-
control module or
sor
Vitosolic sensor.
Lead break,
Check temperature
cylinder tem-
sensor at connec-
perature sen-
tion S3 to Vitosolic
sor
100.
Lead break,
Check temperature
cylinder tem-
sensor % on solar
perature sen-
control module or
sor
Vitosolic sensor.
No flow rate
Check solar circuit
in solar circuit
pump and solar cir-
or flow rate
cuit. Acknowledge
too low, or
fault message.
temperature
limiter has
responded
Solar control
Replace solar con-
module or
trol module or
Vitosolic
Vitosolic
faulty
Impressed
Replace
current anode
impressed current
faulty
anode
Programming
Replace program-
unit faulty
ming unit