total (wet) load. Refer to the weight given in the
technical data tables specific for each model.
6.4

Overall dimensions

A
C
ø80
ø80
ø100
120
120
400
50
115
35
Electric
connection
area
257
100
Cold
water
Gas
inlet
65
52
64
C.h.
flow
Condensate
D.h.w.
drain connection
outlet
area
A --- air intake/flue outlet pipe (co--- axial)
B --- flue outlet pipe ø 80 mm (twin kit)
C --- air intake pipe ø 80 mm (twin kit)
Fig. 6.2 (all dimensions in mm)
B
C
ø80
A, B and C
217
200
142
16
C.h.
return
65
350
200
6.5

Joints

Functions
Gas, c.h. return, c.h. flow
D.c.w. inlet
D.h.w. outlet
Pressure relief valve
Condensate drain
Tab. 6.1 (sizes in mm o.d.)
6.6

Mounting the boiler

1 Take the protective caps off the boiler pipe-
work.
2 Thoroughly clean the connections.
3 Mount the boiler on its bracket.
4 Fix the c.h. valves A and gas cock B (¾") to the
boiler using the ¾" gaskets (Fig. 6.3)
5 Fix the ø 22 mm pipes C (c.h. circuit) to the c.h.
valves A and the ø 22 mm pipe D (gas) to the
cock B using the ¾" gaskets.
6 Repeat the above procedure for the d.c.w. inlet
utilising the ½" cold water inlet valve E, the ø 15
mm copper tail F with its connection nut and
two ½" gaskets.
7 Fix the ø 15 mm copper tail G with the ½" con-
nection nut and a ½" gasket.
A
B
E
Fig. 6.3
8 Connect the pipe H (Fig. 6.4) from the pres-
sure relief valve to the safety discharge pipe-
work.
9 Fit the condensate drain 15 (Fig. 6.4) in the air
brake connected to the drainage pipework.
See also section 5.7 in this manual.
Installation
Pipe sizes (o.d)
ø 22
ø 15
ø 15
ø 15
ø 25 (plastic)
C
D
G
F
A
C
27