Useful Advice; Central Heating; Frost Protection; Periodic Maintenance - Biasi M110B.24SM/C User Manual And Installation Instructions

Wall hung, fan flue, room sealed, high efficiency gas boiler
Hide thumbs Also See for M110B.24SM/C:
Table of Contents

Advertisement

3

Useful advice

3.1

Central heating

For reasonably economical service install a room
thermostat.
Never shut off the radiator in the area where the
room thermostat is installed.
If a radiator (or a convector) does not heat up,
check that no air is present in it and that its valve
is open.
If the ambient temperature is too high, do not alter
the radiator valves. Reduce the central heating
temperature instead by means of the room ther-
mostat and the function selector (8 in Fig. 3.1).
8
Fig. 3.1
3.2

Frost protection

This appliance is provided with a built in anti---
freeze system that operates the boiler when the
temperature is below 5 ˚C
Therefore, when the boiler is not lit and used in
cold weather, with consequent risk of freezing do
not switch off the boiler at the fused spur isola-
tion switch or close the gas inlet cock.
3.3

Periodic maintenance

For efficient and continuous operation of the
boiler, it is advisable to arrange maintenance and
cleaning by an Authorised Service Centre En-
gineer, at least once a year.
During the service, the most important compo-
nents of the boiler will be inspected and cleaned.
This service can be part of a maintenance con-
tract.
In particular, you are advised to have the following
checks carried out:
--- domestic hot water heat exchanger;
--- condensing heat exchanger
--- burner;
--- exhaust fume duct and flue;
12
--- pressurisation of the expansion tank;
--- filling up of the central heating circuit;
--- bleeding of air from the central heating system;
--- general check of the appliance's operation.
3.4

External cleaning

Before carrying out any cleaning, disconnect the
appliance from the electrical mains, using the
fused spur isolation switch fitted adjacent to the
appliance.
To clean the external panels, use a cloth soaked in
soapy water. Do not use solvents, abrasive powd-
ers or sponges.
Do not carry out cleaning of the appliance and/or
its parts with readily flammable substances (for
example petrol, alcohols, naphtha, etc.).
3.5

Operational faults

If the lock---out signal lamp (6 in Fig. 3.2) comes
on
this indicates that the safety lock--- out has stopped
the boiler.
To re--- start the boiler, it is necessary to press the
boiler reset button 7 (Fig. 3.2).
Fig. 3.2
For the first lighting up and following maintenance
procedures for the gas supply, it may be necess-
ary to repeat the resetting operation several times
so as to remove the air present in the pipework.
After five consecutive resetting attempts the reset
button is inhibited. To restore its function it is
necessary to switch the boiler off and on from the
electrical mains, using the fused spur isolation
switch fitted adjacent to the appliance.
Safety lock--- out may occur even in case of a
blockage of the condensate drainage (e.g.
plugged drain pipe).
It is advisable to check the condensate drainage
pipe and traps for cleanness.
In this case and in case of persistent lock--- out call
a competent and responsible Service Engineer.
6