KEEWAY FACT 50 4T Maintenance Manual page 30

Table of Contents

Advertisement

Diagnosis on insufficient battery charging
Y
Adjust or replace the
brake lamp switch.
Leakage current smaller than the required.
Check whether the charging coil of the magnetor is short-circuit.
Y
Replace the
charging coil
Insufficient battery charging
Check whether the brake lamp is always light.
Set the ignition switch to "OFF"; remove the negative cable from the battery;
connect the negative electrode of the ammeter to the battery negative terminal and
the positive electrode to the positive terminal; check current leakage.
1. Check whether the battery electrolyte is enough.
2. Check whether the battery electrolyte is diluted.
3. Check whether the battery electrode plates are
vulcanized or short-circuit.
N
30
N
Leakage current larger than the
required (normally it shall be no
more than 1mA).
Short circuit between the rectifier or
the rectifier regulator or the battery
and the ignition switch.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents