2.5.3 Secondary coil
Attached with spark plug. Measure the impedance between
the wiring side of the spark plug cap and the terminals.
Standard: 5-11KΩ(20 )
It shows good if the impedance is within the range of
standard values.
The impedance ∞ indicates that the coil breaks.
Remove the spark plug cap. Measure the impedance
between
the primary side wire of the ignition coil and the negative
terminal.
Standard: 0.5-5.5KΩ±10%(20 )

2.6 Trigger

* Note
Check the trigger on the engine.
Check
Remove the body guard.
Remove the trigger terminal.
Measure the impedance between the blue/white terminal of
the side wire of the engine and the body GND.
Standard: 100-500Ω(20 )
Replace the magnetor if the measured value exceeds the
standard value.
(白:white 蓝:blue 绿:green)
(磁电机接口:magnetor
绿/红:green/red 白:white)
68
Ω
Ω
白 /绿
蓝 /白
磁 电 机 接 口
DJ7031-2.8-21
DJ621-2.8× 0.5
黑:black
interface