Technical Parameters According To Eu Regulation No. 813/2013 - Wolf CGB-75 Assembly And Operating Instructions Manual

Gas condensing boiler
Table of Contents

Advertisement

Type
Condensing boiler
Low temperature boiler (**)
B11 boiler
Cogeneration space heater
If yes, equipped with a
supplementary heater
Combination heater
Item
Rated heat output
Useful heat output at rated heat
output and high-temperature
regime (*)
Useful heat output at 30% of
rated heat output and low-
temperature regime (**)
Auxiliary electricity consumption
at full load
Auxiliary electricity consumption
at part load
Auxiliary electricity consumption
in standby mode
Seasonal space heating energy
efficiency
Useful efficiency at rated heat
output and high-temperature
regime (*)
Useful efficiency at 30% of rated
heat output and low-temperature
regime (**)
Standby heat loss
Ignition burner power
consumption
Emissions of nitrogen oxides
Contact details
(*) High-temperature regime means 60°C return temperature at heater inlet and 80°C feed temperature at heater outlet.
(**) Low temperature means for condensing boilers 30°C, for low-temperature boilers 37°C and for other heaters 50°C return temperature (at heater inlet).
3062555_201507
Technical parameters according to
EU regulation no. 813/2013
[yes/no]
[yes/no]
[yes/no]
[yes/no]
[yes/no]
[yes/no]
Symbol
Unit
P
kW
rated
P
kW
4
P
kW
1
elmax
kW
elmin
kW
P
kW
SB
n
%
s
n
%
4
n
%
1
P
kW
stby
P
kW
ing
NO
mg/kWh
x
CGB-75
yes
no
no
no
-
no
70
70,1
21,0
0,075
0,025
0,003
93
88,2
97,4
0,086
0,000
20
Wolf GmbH, Industriestraße 1, D-84048 Mainburg
CGB-100
yes
no
no
no
-
no
92
91,9
27,6
0,109
0,028
0,003
93
88,0
97,4
0,085
0,000
24
55