LOCATION
There are several conditions to be considered in
selecting a location for your Erin Stove.
a.
Position in the area to be heated- central
locations are usually best.
b.
Allowances for proper clearances to
combustibles.
NOTE: Sufficient space should be given around the
back and sides of the stove to allow access to the
secondary air control damper.
INSTALLATION CLEARANCES
Maintain at least the following clearances to all
combustible material:
From the front
From the back
From the sides
From the flue pipe
Brick wall minimum clearance.
FLOOR PROTECTION
When installing this heater on a combustible floor, a
floor protector, must be used, consisting of a layer of
noncombustible material at least
or,
" (6mm) thick covered with
1/4
metal. It is required to cover the area under the
heater and to extend to at least 18" (450mm) at the
front and 8" (200mm) to the sides, and rear. This will
provide protection from sparks and embers which
may fall out from the door when stoking or fuelling.
200mm
200mm
450mm
91 cm (36")
30 cm (12")
46 cm (18")
91 cm (36")
straight up only
" (10mm) thick
3/8
" (3mm) sheet
1/8
Fig.10
200mm
6