Problem
None of the cutting decks will lower and Operator
Advisory is displayed on InfoCenter (see Operator
Advisory list in this section).
None of the cutting decks will lower and no Operator
Advisory is displayed on InfoCenter
None of the cutting decks will raise.
Groundsmaster 4500--D/4700--D
NOTE: To lower a cutting deck, the operator must be in
the operator seat and the traction speed must be in the
LOW speed (mow) position. To raise a cutting deck, the
operator must be in the operator seat.
Possible Causes
The HI/LOW speed switch is in the HI speed position.
Operator is not fully depressing the seat switch.
Fuse(s) for TEC controller are faulty.
The seat switch or circuit wiring is faulty.
The HI/LOW speed switch or circuit wiring is faulty.
On Groundsmaster 4500--D, lift switch or circuit wiring
is faulty.
On Groundsmaster 4500--D, lift control manifold
solenoid coil S6 or circuit wiring is faulty.
On Groundsmaster 4700--D, all lift switches or circuit
wiring are faulty.
On Groundsmaster 4700--D, lift control manifold
solenoid coil S1 or circuit wiring is faulty.
A hydraulic problem in the lift/lower circuit exists (see
Troubleshooting section in Chapter 4 - Hydraulic
System).
The TEC--5002 controller is faulty.
Fuse(s) for TEC controller are faulty.
The seat switch or circuit wiring is faulty.
On Groundsmaster 4500--D, lift switch or circuit wiring
is faulty.
On Groundsmaster 4500--D, lift control manifold
solenoid coil S5 or circuit wiring is faulty.
On Groundsmaster 4700--D, all lift switches or circuit
wiring are faulty.
On Groundsmaster 4700--D, lift control manifold
solenoid coil S1 or circuit wiring is faulty.
A hydraulic problem in the lift/lower circuit exists (see
Troubleshooting section in Chapter 4 - Hydraulic
System).
The TEC--5002 controller is faulty.