Service Screen
The service screen (Fig. 14) contains machine opera-
tional information including hours and counts. Values
listed for these service menu items cannot be changed.
If the machine PIN has been entered to allow access to
protected menu items in the settings screen, the protec-
ted service menu items will also be listed and available
in the service screen.
NOTE: If the protected menu items are available, PIN
will be shown in the upper right corner of the InfoCenter
display.
The options listed for hours include the following:
D Key On identifies the number of hours that the igni-
tion switch has been in the ON position.
D Machine Run identifies the number of hours that the
engine has been running.
D PTO On identifies the number of hours that the ma-
chine has been operated with the cutting decks en-
gaged.
D High Range identifies the number of hours that the
machine has been operated in high range speed (trans-
port).
D Service Due identifies the number of hours before
the next scheduled maintenance is due.
The options listed for counts include the following:
D Starts identifies the number of times that the engine
has been started.
D Left Deck (Groundsmaster 4700--D) identifies the
number of times that the left side cutting deck has been
energized.
D Center Deck identifies the number of times that the
center cutting deck has been energized.
D Right Deck (Groundsmaster 4700--D) identifies the
number of times that the right side cutting deck has been
energized.
D Fan Reversals identifies the number of times that
the engine cooling fan has been operated in the reverse
direction.
D Fan - - Coolant identifies the number of times that en-
gine coolant temperature caused the fan speed to
change.
Groundsmaster 4500--D/4700--D
D Fan - - Oil identifies the number of times that hydraul-
ic oil temperature caused the fan speed to change.
The protected menu items include the following:
D Reset Service Due allows the service due hours to
be reset after a scheduled maintenance item is pre-
formed. The Reset Service Due is listed with the other
hours options when the protected items are visable.
D DPF Regeneration provides the necessary proced-
ure for stationary regeneration for the exhaust system
DPF (diesel particulate filter) on machines with a Tier 4
engine (models 30881 and 30882). If the engine ECU
identifies that a stationary DPF regeneration is neces-
sary, an advisory will occur on the InfoCenter and the ne-
cessary steps will be listed in the service screen menu.
D Traction Pedal allows the traction pedal sensor to
be calibrated (see Traction Pedal Position Sensor Calib-
ration in the Adjustments section of this chapter for calib-
ration procedure).
D Fan Reverse provides the necessary inputs to
cause the cooling fan to reverse direction. This protec-
ted menu item allows the demonstration of the fan re-
versal and would never be necessary to use on a
normally functioning machine.
To return to the main menu screen from the service
screen, press the back button (left button).
1
2
5
3
5
1. Service menu
2. Service items
3. Move to menu items
Page 5 - - 11
Hours
Key On:
95.2 Hours
Machine Run:
72.3 Hours
PTO On:
63.7 Hours
4
3
Figure 14
4. Choose menu item
5. Back button