Ferroli Domina Oasi F 24 E Technical Manual page 29

Table of Contents

Advertisement

FERELLA BOIL F 24 - 30 MEL
Heating and tap water temperature probe
These are NTC sensors that increase their resistance as the temperature
decreases and are connected directly to the main card X4 - 24V (heating 12-13,
tap water 10-11). The heating sensor performs the antifreeze function too.
Temperature (˚C)
100
90
80
70
60
50
40
30
25
15
5
Version - 09.2002
DOMINA OASI F 24 - 30 E
KEA AIR COMPACT E
Resistance (K Ohm)
0,68
0,92
1,25
1,7
2,5
3,6
5,3
8
10
15,6
25,3
NTC sensor
33
30
27
24
21
18
15
12
9
6
3
0
0
20
40
60
Temperature (˚C)
80
100
120
29