Gas supply conversion
The unit can function with either Natural Gas or LPG and is factory-set for use with one of the two gases, as
clearly shown on the packing and on the unit's dataplate. Whenever a different gas to that for which the unit
is preset has to be used, a conversion kit will be required, proceeding as follows:
1 Replace the nozzles at the main burner, inserting
the nozzles specified in the technical data table,
according to the type of gas used.
2 Adjust the burner minimum and maximum
pressures, setting the values given in the
technical data chart for the type of gas used.
3 Move the jumper JP02 on the card, as shown in
the diagram:
Natural gas operation
LPG operation
4 Apply the sticker, contained in the conversion
kit, near the dataplate as proof of the conversion.