Host Parameters - Symbol DS6707 Product Reference Manual

Digital imager scanner
Hide thumbs Also See for SYMBOL DS6707:
Table of Contents

Advertisement

8 - 4
Symbol DS6707 Digital Imager Scanner Product Reference Guide
RS-232 Host Parameters
Various RS-232 hosts use their own parameter default settings. Selecting standard, ICL, Fujitsu, Wincor-Nixdorf
Mode A, Wincor-Nixdorf Mode B, OPOS/JPOS, Olivetti, or Omron sets the defaults listed in
Terminal Specific RS-232
Table 8-2
Parameter
Transmit Code ID
Yes
Data Transmission
Data/Suffix
Format
Suffix
CR (1013)
Baud Rate
9600
Parity
Even
Hardware
RTS/CTS
Handshaking
Option 3
Software
None
Handshaking
Serial Response
9.9 Sec.
Time-out
Stop Bit Select
One
ASCII Format
8-Bit
Beep On <BEL>
Disable
RTS Line State
High
Prefix
None
*In the Nixdorf Mode B, if CTS is low, scanning is disabled. When CTS is high, scanning is enabled.
**If you select Nixdorf Mode B without connecting the digital imager scanner to the proper host, it may
appear unable to scan. If this happens, scan a different RS-232 host type within 5 seconds of cycling power to
the digital imager scanner.
Wincor-Nixdorf
ICL
Fujitsu
Yes
Yes
Data/Suffix
Data/Suffix
CR (1013)
CR (1013)
9600
9600
None
Odd
None
RTS/CTS
Option 3
None
None
2 Sec.
9.9 Sec.
One
One
8-Bit
8-Bit
Disable
Disable
Low
Low
None
None
Wincor-Nixdorf
Mode B/
Mode A
OPOS/JPOS
Yes
Data/Suffix
CR (1013)
9600
Odd
RTS/CTS Option 3
None
9.9 Sec.
One
8-Bit
Disable
Low = No data to
send
None
Table
8-2.
Olivetti
Omron
Yes
Yes
Prefix/Data/
Data/Suffix
Suffix
ETX (1002)
CR (1013)
9600
9600
Even
None
None
None
Ack/Nak
None
9.9 Sec.
9.9 Sec.
One
One
7-Bit
8-Bit
Disable
Disable
Low
High
STX (1003)
None

Hide quick links:

Advertisement

Table of Contents
loading