Controls and Indicators Interface

Controls and Indicators Interface
The W24 incorporates several interface signals for controlling and monitoring the module's
operation. The following paragraphs describes these signals and their operation.
Table 2-12

Reset

The RESET_N output signal indicates the W24's operating status. This signal is set high after
power up, when W24 is operating. It is set low when W24 is powered off.
When the RESET_N signal is low, the W24 interface signals are disabled and do not represent
any valid data or state. Furthermore, any input signals connected to the W24 interface must be
disabled (tri-state) or set low when RESET_N is low.

VREF Reference Regulator

The W24 incorporates a regulated voltage output, VREF. The regulator provides a 2.8V output
for use by the customer application. This regulator can source up to 100 mA of current to power
any external digital circuits. VREF voltage is present whenever the W24 is powered up,
regardless of it's mode of operation.
28
gives a description of the controls and indicators signals.
Table 2-12: Controls and Indicators
Pin #
Pin Name
RESET_N
25
VREF
27
WKUPO_N
26
WKUPI_N
16
ANT_DET
41
TXEN_N
39
GPRS
49
WIFI_LED_LCD_RS
60
MSEL_UID
45
Module Hardware Description
Description
W24 system readiness output
indicator. When high, W24 is
operating.
2.75V regulated output.
Supplies up to 100mA to the
external circuits.
Host application wake-up signal
indicator.
Device application wake-up sig-
nal control.
Antenna physical connection
detect indicator.
Transmission burst indication.
GPRS/EGPRS coverage indica-
tor.
Wi-Fi Activity LED indicator.
Mode Select.