4. LAMP & LAMP HOUSE
W
ARNING
XENON LAMP HANDLING OR SERVICE. ONLY TRAINED AND QUALIFIED TECHNICAL SERVICE PERSONNEL
ARE ALLOWED TO HANDLE THE XENON LAMP.
C
AUTION
of the bulb increases the pressure to a level at which the bulb may explode if not handled in strict accordance
to the manufacturer's instructions. The bulb is stable at room temperature, but may still explode if dropped or
otherwise mishandled. Whenever the lamp house, containing a xenon lamp, has to be dismantled or whenever
the protective container or cloth has to be removed from the xenon lamp, authorized protective clothing MUST
be worn!
W
ARNING
W
ARNING
W
ARNING
Overview
•
Introduction
•
Removal of the lamp house
•
Removal of the xenon lamp
•
Installation of the xenon bulb lamp
•
Installation of the lamp house
•
Resetting the lamp parameters
•
Realignment of the lamp in its reflector
R59770491 DP2K-32B 30/04/2010
:
DO NOT PERMIT UNAUTHORIZED PERSONNEL TO PERFORM OR ATTEMPT ANY PHASE OF
:
Xenon compact arc lamps are highly pressurized. When ignited, the normal operating temperature
:
Always wear face protection (full face shield with neck protector) when handling xenon lamps.
:
Always wear protective clothing (welder's jacket) when handling xenon lamps.
:
Always wear clean leather gloves with wrist protectors when handling xenon lamps.
4. Lamp & lamp house
31