Lnr110 Series Troubleshooting - Lorex LNR110 Series Instruction Manual

Table of Contents

Advertisement

21

LNR110 Series Troubleshooting

When a malfunction occurs, it may not be serious and can be corrected easily. The follow-
ing describes the most common problems and solutions. Please refer to the following be-
fore calling Lorex Technical Support:
Error
Possible Causes
NVR is not receiving
power, or is not power-
ing up.
There is no picture on
selected channels /
camera picture is not
being displayed.
Hard drive is not de-
tected by the system.
Hard drive is full and the
unit is no longer
recording.
#LX400070; r. 1.0/27147/27147; en-US
Solutions
Cable from power
Confirm that all cables are connected
adapter is loose or is
correctly.
unplugged.
Confirm that the power adapter is se-
curely connected to the back of the unit.
Cables are connected,
Confirm that the unit is powered on
but NVR is not receiv-
(LED indicators on the front should be
ing sufficient power.
ON).
If the unit is connected through a power
bar or surge protector, try bypassing
the bar and connecting the power di-
rectly to the wall outlet.
Confirm that there is power at the
outlet:
Camera cables are
Disconnect and reconnect the cable at
the NVR and at the camera.
loose or have become
Try moving the camera to another chan-
disconnected.
nel or use another cable.
If your cameras are not using PoE,
make sure they are using the correct
power source according to the
specifications.
Make sure your cameras are connected
Camera/NVR connec-
tion to LAN has be-
to the same LAN as the NVR.
come interrupted.
Make sure any routers or switches in
between the NVR and IP cameras are
powered on.
Hard drive cables are
Remove the housing and check that
loose or not properly
hard drive cables are firmly connected.
connected.
Hard drive has not
For details, see 13.3.17 Formatting the
been initialized (format-
Hard Drive, page 67.
ted) by the system.
There is no hard drive
Open the housing and install a 3.5" SA-
in the system.
TA hard drive.
Overwrite is not
From the Main Menu, select General.
enabled.
Beside HDD Full, select Overwrite.
Click OK to save settings. This enables
the system to continuously record by
overwriting data once the hard drive is
full.
Connect the power cable to another
outlet.
Test the outlet with another plugged
device (such as an electric calcula-
tor or phone charger).
169

Hide quick links:

Advertisement

Table of Contents
loading