QQ
3 7 63 1515 0
DVD SECTION
When the optical pick-up assy is replaced, perform the "Executing
IOP Measurement".
Executing IOP Measurement (See page 30)
TUNER SECTION
[FM Tune Level Check]
SET
Procedure:
1. Turn the power on.
2. Input the following signal from Signal Generator to FM
antenna input directly.
* Carrier Freq : A = 87.5 MHz, B = 98 MHz, C = 108 MHz
Deviation
: 75 kHz
Modulation : 1 kHz
ANT input : 35 dBu (EMF)
TE
L 13942296513
Note: Please use 75 ohm "coaxial cable" to connect SG and the set. You
cannot use video cable for checking.
Please use SG whose output impedance is 75 ohm.
3. Set to FM tuner function and tune A, B and C signals.
4. Confirm "TUNED" is lit on the display for A, B and C signals.
The mark of "TUNED" means "The selected station signal is
received in good condition."
www
.
http://www.xiaoyu163.com

ELECTRICAL ADJUSTMENT

generator
OUT (75 Ω )
x
ao
u163
y
i
http://www.xiaoyu163.com
SECTION 5
2 9
8
DIAT SECTION
DIAT SIGNAL RF LEVEL ADJUSTMENT
This adjustment is performed in order to adjust the transmission
distance of RF signal for DIAT communication.
Connection:
DIAT-TX board
Procedure:
1. Connect the oscilloscope to TP1815 and GND on the DIAT-
TX board.
2. Connect DIR-T1 to DIR-T1 jack
(DIAT-TX board: J1801).
3. Confirm trigger is locked.
4. Adjust RV1801 on the DIAT-TX board so that the center of
waveform becomes 2.2 to 2.4 Vp-p.
RF Signal Reference Waveform
Q Q
3
6 7
1 3
1 5
Adjustment Location:
– DIAT- TX Board (SIDE A) –
CN1801
co
.
HCD-DZ830W/DZ850KW
9 4
2 8
oscilloscope
TP1815
VOLT/DIV : 500 mV
TIME/DIV : 500 ns
level : 2.2 to 2.4 Vp-p
0 5
8
2 9
9 4
2 8
J1801
TP1815
RV1801
CN1802