Heatilator ODYSSEY ODY42 Installation & Operating Instructions Manual
Heatilator ODYSSEY ODY42 Installation & Operating Instructions Manual

Heatilator ODYSSEY ODY42 Installation & Operating Instructions Manual

Radiant fireplace with factory installed gas log set

Advertisement

INSTALLATION & OPERATING
WITH FACTORY INSTALLED GAS LOG SET
01/04
INSTRUCTIONS
RADIANT FIREPLACE
ODY42
CAUTION:
ODYSSEY
ODY42
WARNING:
is not followed exactly, a fire or explosion
may result causing property damage, personal
injury or loss of life.
— Do not store or use gasoline or other flammable
— What to do if you smell gas
— Installation and service must be performed by a
Note:
content.
31818 Rev J
If the information in this manual
vapors and liquids in the vicinity of this or any
other appliance.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call the
fire department.
qualified installer, service agency or the gas
supplier.
WARNING!
An arrow (Æ found in the text signifies change in
1

Advertisement

Table of Contents
loading

Summary of Contents for Heatilator ODYSSEY ODY42

  • Page 1 INSTALLATION & OPERATING INSTRUCTIONS ODYSSEY ODY42 RADIANT FIREPLACE WITH FACTORY INSTALLED GAS LOG SET WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. —...
  • Page 2: Table Of Contents

    10. Due to high temperatures, the fireplace should be located out of traffic areas and away from furniture and draperies. 11. Solid fuels cannot be burned in a fireplace where the decorative gas appliance is installed. 12. In order to install Heatilator® fireplace models ODY42 and ODY42L in the state of Massachusetts, the Commonwealth of Massachusetts requires the following: The damper must be removed.
  • Page 3 ODYSSEY SERIES FIREPLACE WITH GAS LOG SET DESIGN AND INSTALLATION CONSIDERATION When selecting a location for your B-Vent appliance, it is important to evaluate a number of considerations. Modern construction techniques can create conditions that may not allow your vent to draft properly. This may result in spillage from your B-Vent appliance, as well as cause other combustion appliances to operate incorrectly.
  • Page 4: Listings And Code Approvals

    . If any assistance is required during The Odyssey Series fireplace with factory installed gas log installation, please contact your local dealer or the Heatilator set has been tested and listed for use with the optional Technical Services Department, Hearth & Home Technologies components given on page 5.
  • Page 5: Fireplace System Components

    ODYSSEY SERIES FIREPLACE WITH GAS LOG SET C. FIREPLACE SYSTEM COMPONENTS The table below, together with the pictures on the following pages show only those components which may be safely used with this fireplace. WARNING! s i l z i l s f f °...
  • Page 6 ODYSSEY SERIES FIREPLACE WITH GAS LOG SET Dimensions REMOTE CONTROLS 31818 Rev J 01/04...
  • Page 7 ODYSSEY SERIES FIREPLACE WITH GAS LOG SET " 6 " 4 " 2 " 4 " 8 " 4 " 4 " 4 ° 5 ° 0 " 6 " 4 " 8 " 4 i t c Æ ° 0 "...
  • Page 8 ODYSSEY SERIES FIREPLACE WITH GAS LOG SET 31818 Rev J 01/04...
  • Page 9: Pre-Installation Preparation

    ODYSSEY SERIES FIREPLACE WITH GAS LOG SET D. PRE-INSTALLATION PREPARATION 1. Fireplace Locations and Space Requirements Several options are available to you when choosing a location for your fireplace. This fireplace may be used as a room divider, installed along a wall, across a corner or use an exterior chase. The room must have a minimum volume of 3,750 cubic feet.
  • Page 10 ODYSSEY SERIES FIREPLACE WITH GAS LOG SET WARNING! 2. Frame the Fireplace Figure 4 shows a typical framing (using 2 x 4 lumber) of the fireplace, assuming combustible materials are used. All required clearances to combustibles around the fireplace must be adhered to. Any framing across the top of the fireplace must be above the level of the top standoffs.
  • Page 11: Hearth Extensions

    ODYSSEY SERIES FIREPLACE WITH GAS LOG SET 3. Hearth Extensions It is recommended that a hearth extension be installed with all fireplaces. In the event the fireplace is converted to burn solid (wood) fuel, a hearth extension must be installed with all fireplaces to protect the combustible floor in front of the fireplace from both radiant heat and sparks.
  • Page 12: Chimney Requirements

    ODYSSEY SERIES FIREPLACE WITH GAS LOG SET 4. Sidewalls/Surrounds Adjacent combustible side walls must be located a minimum of 12” from the fireplace opening. See Figure 7. If you are using a decorative surround constructed of combustible material, it must be located within the shaded area defined in Figure 7.
  • Page 13 ODYSSEY SERIES FIREPLACE WITH GAS LOG SET The effective height of the fireplace assembly is The “B” dimensions that coincide with the “A” 33”. Effective height of fireplace assembly is dimensions represent the required vertical measured from base of the fireplace to top of clearance that is needed to complete the offset starter collar.
  • Page 14 ODYSSEY SERIES FIREPLACE WITH GAS LOG SET 2. Chimney Height Requirements (Above the Roof Line) Major building codes specify a minimum chimney height above the roof top. These specifications are summarized in what is known as the “Ten Foot Rule.” This rule states: If the horizontal distance from the side of the chimney to the peak of the roof is 10 feet or less, the top of the chimney must be at least 2 feet above the peak of the roof, but never less than 3 feet in overall height above the highest point where it passes through the roof.
  • Page 15: Step-By-Step Installation Of Fireplace System

    ODYSSEY SERIES FIREPLACE WITH GAS LOG SET F. STEP-BY-STEP INSTALLATION OF FIREPLACE SYSTEM WARNING! 1. Position the Fireplace This fireplace may be placed on either a combustible or noncombustible continuous surface. Follow the instructions for framing on pages 9-12. 2. Place the Protective Metal Hearth Strips Included with your fireplace you will find two metal hearth strips measuring approximately 4”...
  • Page 16 ODYSSEY SERIES FIREPLACE WITH GAS LOG SET 4. Assembling Chimney Sections CAUTION: Attach either a straight chimney section or an offset to the top of the fireplace depending on your installation requirement. See Figure 11. Chimney sections are locked together by pushing downward until the top section meets the top head on the lower section.
  • Page 17 ODYSSEY SERIES FIREPLACE WITH GAS LOG SET WARNING! 10. Mark the Exit Point of the Roof Locate the point where the chimney will exit the roof by plumbing down to the center of the chimney. Drive a nail up through the roof to mark the center. See Figure 16. 11.
  • Page 18 (TR344), a round telescoping termination cap (TR342), or a square termination cap (ST375, TS345, TS345P). A chase installation must use a chase top. Chase tops are available from you Heatilator distributor. See page 19 for building a chase. 17. Install the Firescreen 14.
  • Page 19: Constructing A Chase

    ODYSSEY SERIES FIREPLACE WITH GAS LOG SET G. CONSTRUCTING A CHASE A chase is a vertical boxlike enclosure built around the chimney 1. Materials for the Chase and fireplace. A chase may be constructed for the fireplace The chase is constructed using framing materials much and chimney or for the chimney only.
  • Page 20 ODYSSEY SERIES FIREPLACE WITH GAS LOG SET 2. Installing a Termination Cap on a Chase Enclosed Chimney Construct a chase of desired materials maintaining a minimum 2” air space around the chimney. WARNING! WARNING! WARNING! Install the chimney sections up through the chase enclosure.
  • Page 21: Utilities

    Input should be reduced 4% for each 1000 feet above sea level. Check with the local gas utility for proper orifice size identification. The correct orifice is available from your Heatilator distributor. For Canada, fireplaces are certified for elevations from 0-4500 feet. When installing this fireplace at an elevation between 0-4500 feet in Canada, the input rating does not need to be reduced.
  • Page 22: Junction Box Installation

    ODYSSEY SERIES FIREPLACE WITH GAS LOG SET 3. Gas Pressure Pressure taps are included on the front face of the gas control valve. Pressure taps are immediately upstream of the gas supply connection and accessible for test gauge connection. Tables 3 and 4 show optimum gas pressure information. Consult your local gas company for assistance in determining the proper orifice for your altitude or refer to 4.
  • Page 23 ODYSSEY SERIES FIREPLACE WITH GAS LOG SET Note: WARNING! This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with or the 6. Standing Pilot Ignition A wiring diagram is shown in Figure 25.
  • Page 24: Appliance Preparation

    ODYSSEY SERIES FIREPLACE WITH GAS LOG SET I. APPLIANCE PREPARATION 3. Place the Rock Wool 1. Log Set Place approximately 1/2” diameter pieces of rock wool Unwrap the top right log shipped inside the valve under the front logs, on the bottom hearth log. Place the compartment and position over pins in proper location.
  • Page 25: Operating Instructions

    ODYSSEY SERIES FIREPLACE WITH GAS LOG SET J. OPERATING INSTRUCTIONS Lighting Instructions for Standing Pilot FOR YOUR SAFETY READ BEFORE LIGHTING THE STANDING PILOT. WARNING! This appliance has a pilot which must be lighted by • If you cannot reach your gas supplier, call the fire hand.
  • Page 26: Seasonal Check List

    ODYSSEY SERIES FIREPLACE WITH GAS LOG SET K. SEASONAL CHECK LIST WARNING! CAUTION: Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc.
  • Page 27: Start-Up Issues

    ODYSSEY SERIES FIREPLACE WITH GAS LOG SET 6. Fuel 5. Standing Pilot Operation Do not burn wood or other material in this fireplace with the gas logs installed. The ODYCKW Conversion Kit is available to convert this fireplace to burn solid fuel (wood). Turn the wall switch to “ON”.
  • Page 28: Maintenance Instructions

    ODYSSEY SERIES FIREPLACE WITH GAS LOG SET M. MAINTENANCE INSTRUCTIONS 1. Clean the Burner and Control Compartment Keep the burner and control compartment clean by brushing and vacuuming at least once a year. Always turn off the wall switch (or remote control) and gas valve before cleaning.
  • Page 29: Log Removal/Replacement

    Lift up on the assembly to remove it from the fireplace and set it aside, being careful not to damage any of the logs. See Figure 37. Reverse the order to reinstall the logs Visit our Website at www.heatilator.com for a dealer/distributor near you! 01/04 31818 Rev J...
  • Page 30 ODYSSEY SERIES FIREPLACE WITH GAS LOG SET O. REPLACEMENT PARTS Replacement parts are available from your distributor/dealer. f i r f i r f i r t i l i l u l l i " 0 ° 31818 Rev J 01/04...
  • Page 31: Index

    ODYSSEY SERIES FIREPLACE WITH GAS LOG SET Index Air Kit 18 Gas Codes 4, 22 Offset Chart 13 Air Shutter 28 Gas Conversions 22 Offsets and Returns 12 Æ Attic Insulation Shield 7, 16, 17 Gas Line 21 Outside Air 9, 26 Gas Pressure 22 Outside Air Kit 2, 6, 9, 18 Glass Doors 6, 18, 26...
  • Page 32 If the Heatilator Appliance is found to be defective in either material or workmanship within one year of the date of original installation, HHT will provide replacement parts at no charge and pay reasonable labor and freight costs, and is for the period of one year following the date of original installation of the Appliance.