INSTALLATION GUIDE

Ideal installation locations include:
Indoor Unit
S A location where there are no obstacles near inlet and outlet area.
S A location which can bear the weight of indoor unit.
S Do not install indoor units near a direct source of heat such as
direct sunlight or a heating appliance.
S A location which provides appropriate clearances as outlined in
Fig. 6. Be sure to leave enough distance to allow access for
routine maintenance. The installation site should be 66 in (1676
mm) or more above the floor.
S Select a place away from potential electronic interference.
S Select a place where the filter can be easily removed.
Outdoor Unit
S A location which is convenient to installation and not exposed to
strong wind.
S A location which can bear the weight of outdoor unit and where
the outdoor unit can be mounted in a level position.
S A location which provides appropriate clearances as outlined in
Fig. 6.
S Do not install the indoor or outdoor units in a location with
special environmental conditions.
S Make sure the outdoor unit is installed in accordance with the
installation instructions and is convenient for maintenance and
repair.
S See the refrigerant piping table for the maximum height
difference between indoor and outdoor units and the maximum
length of the connecting tubing.

INDOOR UNIT INSTALLATION

INSTALL MOUNTING PLATE

1. Carefully remove the mounting plate from the unit box.
2. The mounting plate should be located horizontally and level
on the wall.
All minimum spacings shown in Fig. 7
through Fig. 10 should be maintained.
3. If the wall is block, brick, concrete or similar material, drill
.2" (5 mm) diameter holes and insert anchors for the ap-
propriate mounting screws.
4. Attach the mounting plate to the wall.
Wall
See Hole
Size Tables
Mark middle
6 in.
(Rear piping hole)
Fig. 11 --- Mounting Plate Spacing
50 (126.5)
Unit: IN. (mm)
Fig. 7 --- 09 and 12K Mounting Plate Spacing
34.1 (865)
6.9
21.3 (540)
(175)
Φ55
1.6 (40)
Unit: IN. (mm)
Fig. 8 --- 18k Mounting Plate Spacing
39.7 (1008)
5.1 (130)
27.0 (685)
Φ55
2.0 (50)
3.9
Unit: IN. (mm)
(100)
Fig. 9 --- 24k Mounting Plate Spacing
10.0
29.4
(254.0)
(746.8)
Unit: IN. (mm)
Fig. 10 --- 30/36k Mounting Plate Spacing
Level
6 in.
(Rear piping hole)
8
30.3 (770)
21.6 (548.5)
5.9
(150)
Φ55
1.6 (40)
7.6 (193)
Φ55
2.0 (50)
4.9
(124)
13.7
(348.0)
Wall
See Hole
Size Tables
A12537
A12534
A12535
A12536
A12584