Carrier 40GVC / 38GVC Product Data

Carrier 40GVC / 38GVC Product Data

High-wall ductless split systems size 009k - 036k

Advertisement

40GVC / 38GVC
40GVQ / 38GVQ
High---Wall Ductless Split Systems
Size 009K --- 036K
The ideal compliment to your ducted system when it is impractical
or prohibitively expensive to use ductwork.

Product Data

INDUSTRY LEADING
FEATURES / BENEFITS
AN INEXPENSIVE AND CREATIVE
SOLUTION TO DESIGN PROBLEMS.
The 38GVC(Q)/40GVC(Q) inverter driven ductless split systems
are a matched combination of an outdoor condensing unit and an
indoor fan coil unit connected only by refrigerant tubing and wires.
The fan coil is mounted on the wall, near the ceiling. This selection
of fan coils permits inexpensive and creative solutions to design
problems such as:
S
S
S
S
These compact indoor fan coil units take up very little space in the
room and do not obstruct windows. The fan coils are attractively
styled to blend with most room decors.
components incorporate innovative technology to provide reliable
cooling performance at low sound levels.
Add- -on to current space (sun room)
Special space requirements
When adding air conditioning to spaces that are heated
by hydronic or electric heat and have no ductwork.
Historical renovations or any
preserving the look of the original structure is essential.
application where
Advanced system

Advertisement

Table of Contents
loading

Summary of Contents for Carrier 40GVC / 38GVC

  • Page 1: Product Data

    40GVC / 38GVC 40GVQ / 38GVQ High---Wall Ductless Split Systems Size 009K --- 036K Product Data INDUSTRY LEADING FEATURES / BENEFITS AN INEXPENSIVE AND CREATIVE SOLUTION TO DESIGN PROBLEMS. The 38GVC(Q)/40GVC(Q) inverter driven ductless split systems are a matched combination of an outdoor condensing unit and an indoor fan coil unit connected only by refrigerant tubing and wires.
  • Page 2 INVERTER TECHNOLOGY - - COMFORT FAST INSTALLATION The inverter driven compressor is designed to run at various input This compact ductless split system is simple to install. A mounting power frequencies (Hz) which controls the motor speed of the bracket is standard with the indoor units and only wires and piping compressor.
  • Page 3: Model Number Nomenclature

    MODEL NUMBER NOMENCLATURE INDOOR UNIT --- --- --- Voltage 1 --- 115 ---1 ---60 Fan Coil Unit 3 --- 208/230 ---1 ---60 Nominal Capacity 009 --- 3/4 Ton 012 --- 1 Ton 018 --- 1 ---1/2 Ton Unit Type 024 --- 2 Ton GVC --- Cooling Only 030 --- 2 ---1/2 Ton (HP only) GVQ --- Heat Pump...
  • Page 4: Standard Features And Accessories

    STANDARD FEATURES AND ACCESSORIES INDOOR UNITS Ease Of Installation Mounting Brackets Low Voltage Controls Comfort Features Microprocessor Controls Wireless Remote Control Rapid Cooling/Heating Automatic Air Sweep Cold Blow Prevention Continuous Fan * Auto Restart Feature Memory Function Auto Changeover on Heat Pumps Dry Function Energy Saving Features Inverter Driven Compressor...
  • Page 5 DIMENSIONS - - INDOOR A12377 Net Operating Weight Unit Size In. (mm) In. (mm) In. (mm) Lbs. (Kg) 30.3 (770) 11.1 (283) 7.9 (201) 18.7 (8.5) 12 K 30.3 (770) 11.1 (283) 7.9 (201) 19.8 (9.0) 18 K 34.0 (865) 12.0 (305) 8.5 (215) 26.4 (12)
  • Page 6 DIMENSIONS - - OUTDOOR CONTINUED 25.9 (658) 10.8 (274) 28.0 (711) 12.5 (318) 18.5 (470) Unit: IN. (mm) Unit: IN. (mm) A12532 Fig. 4 – 12K 230V (Net Operating Weight: 63.8 lbs. / 30 kg) 13.4 (340) 35.0 (890) 37.9 (963) 15.6 (396) 22.0 (560) Unit: IN.
  • Page 7 DIMENSIONS - - OUTDOOR CONTINUED 14.6 (914.4) (370.8) 16.7 38.6 (424.2) (980.4) (609.6) in. (mm) A12379 Fig. 6 – 30K and 36K (Net Operating Weight: 30K = 154 lbs. / 70 kg; 36K = 161 lbs. / 73 kg)
  • Page 8: Indoor Unit

    CLEARANCES Indoor Unit Distance to Ceiling 6 in (152 mm) Distance to Wall Distance to Wall 6 in (152 mm) 6 in (152 mm) NOTE: Refrigerant lines may be routed in any of the (4) directions, right, right rear, left, or left rear. Distance in Front of Unit Distance to Floor See instructions for details...
  • Page 9 PHYSICAL DATA - - 38GVC Outdoor Unit 38GVC System Voltage 115 ---1 ---60 208/230 ---1 ---60 Control Voltage Low Voltage Pulse DC Rated Cooling Capacity (Btuh) 9,000 11,800 12,000 18,000 22,000 33,600 Cooling. Capacity Range 3,500 --- 11,000 3,300 --- 12,500 3,300 --- 12,500 4,500 --- 21,000 6,400 --- 24,000...
  • Page 10 PHYSICAL DATA CONTINUED - - 40GVC Indoor Unit 40GVC System Voltage 115 V 208/230 ---1 ---60 Control Voltage Low Voltage Pulse DC Electrical Connections Indoor Unit Powered From Outdoor Unit Rated Cooling Capacity (Btuh) 9,000 11,800 12,000 18,000 22,000 33,600 Operating Weight lb.
  • Page 11 PHYSICAL DATA CONTINUED - - 38GVQ Outdoor Unit 38GVQ System Voltage 115--- 1--- 60 208/230--- 1--- 60 Control Voltage Low Voltage Pulse DC Rated Cooling Capacity 9,000 11,800 12,000 18,000 22,000 28,000 33,600 (Btuh) Cooling. Capacity Range 3,500 --- 11,000 3,300 --- 12,500 3,300 --- 12,500 4,500 --- 21,000...
  • Page 12 PHYSICAL DATA CONTINUED - - 40GVQ Indoor Unit 40GVQ System Voltage 115 V 208/230--- 1--- 60 Control Voltage Low Voltage Pulse DC Electrical Connections Indoor Unit Powered From Outdoor Unit Rated Cooling Capacity (Btuh) 9,000 11,800 12,000 18,000 22,000 28,000 33,600 Rated Heating Capacity (Btuh) 10,000...
  • Page 13: System Operating Conditions

    If unit is exposed to strong winds, it is Long Line Applications: recommended that a wind baffle be used. Contact your Carrier representative for drawings. Do not install the outdoor or indoor 1. No change in line sizing is required.
  • Page 14: Drain Connections

    DRAIN CONNECTIONS DEHUMIDIFICATION (DRY) - - in Dehumidification (Dry) mode, the system dries, filters and slightly cools room temperature. Install drains to meet the local sanitation codes. If adequate gravity This mode does not take place of a dehumidifier. drainage cannot be provided, a field installed condensate pump In addition to the above modes that are selected by using the accessory should be used.
  • Page 15: Air Throw Data

    AIR THROW DATA Approximate Air Throw ft. (m) Unit Size Medium High Turbo 18 (5.5) 21 (6.4) 23 (7.0) 28 (8.5) 12 K 20 (6.1) 23 (7.0) 25 (7.6) 30 (9.1) 18 K 22 (6.7) 27 (8.2) 33 (10.1) 39 (11.9) 24 K 25 (7.6) 29 (8.8)
  • Page 16: Guide Specifications

    GUIDE SPECIFICATIONS HORIZONTAL DISCHARGE OUTDOOR UNITS Size Range: 3/4 - - 3 Ton Nominal Cooling and Heating Capacity Carrier Model Number: 38GVC(Q) PART 1 – GENERAL 1.01 System Description D. Compressor 1. Compressor shall be fully hermetic variable speed rotary A.
  • Page 17 GUIDE SPECIFICATIONS INDOOR WALL- - MOUNTED DUCT- - FREE UNITS Size Range: 3/4 - - 3 Ton Nominal Cooling and Heating Capacity Carrier Model Number: 40GVC(Q) PART 1 – GENERAL 1.01 System Description 4. Automatic air sweep control to provide on or off activation of air sweep louvers.
  • Page 18 Catalog No. 38---40GVCQ---1PD Copyright 2013 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Edition Date:01/13 Replaces: New Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.