Protecting The Heating Installation Against Frost; Troubleshooting; Detecting And Rectifying Faults; Calling Up (Live Monitor) Status Codes - Vaillant ecoTEC plus VU Operating Instructions Manual

Table of Contents

Advertisement

5 Troubleshooting

4.14.2 Filling the heating installation
Caution.
Risk of material damage due to heating
water that is extremely calciferous or cor-
rosive or contaminated by chemicals.
Unsuitable tap water damages the seals
and diaphragms, blocks components in the
product and heating installation through
which the water flows and causes noise.
Only fill the heating installation with suit-
able heating water.
In case of doubt, ask a competent person
for details.
1.
Ask a competent person where the filling cock is loc-
ated.
2.
Connect the filling cock to a hot water supply in the way
you were told by the competent person.
3.
Open all radiator valves (thermostatic radiator valves) of
the heating installation.
4.
Open the hot water supply.
5.
Turn the filling cock on slowly and allow water to flow in
until the required filling pressure has been reached.
6.
Close the hot water supply.
7.
Purge all radiators.
8.
Check the filling pressure in the display.
9.
Top up with more water if necessary.
10. Close the filling cock.
11. Return to the basic display. (→ Page 7)
4.15
Protecting the heating installation against
frost
4.15.1 Frost protection function
Caution.
Risk of material damage due to frost.
The frost protection function cannot guaran-
tee flow through the entire heating installa-
tion, which means that parts of the heating
installation may freeze and therefore become
damaged.
During a period of frost, ensure that the
heating installation remains in operation
and that all rooms are sufficiently heated,
even when you are away.
Note
To keep the frost protection devices active, you
should switch your product on and off using the
controller, if one is provided.
If the heating flow temperature falls below 5 °C when the
on/off button is on, the product comes into operation and
heats the circulating water to approx. 30 °C on both the heat-
ing side and the hot water side (if available).
10
4.15.2 Draining the heating installation
When the unit is switched off for an extended period, frost
protection can be guaranteed by completely draining the
heating installation and the product.
Consult a competent person about this.
5
Troubleshooting
5.1

Detecting and rectifying faults

If faults occur, proceed in accordance with the table in
the appendix.
Troubleshooting (→ Page 13)
If the fault cannot be eliminated using the specified
measures or if fault messages (F.xx) occur, contact a
competent person.
5.2

Calling up (Live monitor) status codes

Press
and
at the same time.
Status codes – Overview (→ Page 12)
The current operating status (status code) is shown
on the display.
6

Care and maintenance

6.1

Maintenance

An annual inspection of the product carried out by a compet-
ent person is a prerequisite for ensuring that the product is
permanently ready and safe for operation, reliable, and has a
long working life.
6.2

Caring for the product

Caution.
Risk of material damage caused by un-
suitable cleaning agents.
Do not use sprays, scouring agents, de-
tergents, solvents or cleaning agents that
contain chlorine.
Clean the casing with a damp cloth and a little solvent-
free soap.
6.3

Reading maintenance messages

If the
symbol is shown on the display, the product requires
maintenance work.
The product is not in fault mode but continues to operate.
Consult a competent person about this.
If the water pressure is flashing at the same time, simply
add more heating water.
Operating instructions ecoTEC plus 0020220342_01

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecotec plus vuw

Table of Contents