3.13.4
Adjusting the tension of the stack processing motor belt
(1)
Remove the right inner cover and the rear cover.
(2)
Remove the 2 mounting screws, and detach
the grip unit.
(3)
Loosen the screw on the tension arm plate.
(The tension arm plate will be pulled under
tension by the tension spring.)
e-STUDIO281c/351c/451c ADJUSTMENT
Screw
Screw
3 - 82
Grip unit
Screw
Fig.3-75
Tension arm plate
Fig.3-76
June 2005 © TOSHIBA TEC