Sony HTC-V5550 Service Manual page 13

Hide thumbs Also See for HTC-V5550:
Table of Contents

Advertisement

QQ
3 7 63 1515 0
Record Bias Adjustment (Deck B)
Procedure:
Press the p (CD) button while pressing the DIRECTION
1.
MODE button.
While pressing the p (CD) button, press the ª (TAPE A)
2.
button, set the function to "deck B".
Insert a tape into deck B, press the r REC button, and then
3.
press the ( button to start recording.
4.
Mode: Record
AF OSC
attenuator
5.
Mode: Playback
recorded
position
set
TE
L 13942296513
6.
Confirm playback the signal recorded in step 2 become
adjustment level as follows.
If these levels do not adjustment level, adjust the RV341 (L-
CH) and RV441 (R-CH) on the AUDIO board to repeat steps 3
and 4.
Adjustment level: The playback output of 10 kHz level difference
against 315 Hz reference should be ± 1.0 dB.
Adjustment Location: AUDIO board
Adjustment Location
[AUDIO BOARD] (Conductor Side)
RV341(Lch),RV441(Rch)
Record Bias
RV301 RV401
RV441 RV341
RV301(Lch),RV401(Rch)
Playback Level (Deck B)
www
.
http://www.xiaoyu163.com
INPUT POINT
1) 315 Hz
} 50 mV (–23.8 dB)
2) 10 kHz
blank tape
CS-123
600 Ω
PFJ-1
set
level meter
PFJ-1
output
point
RV311(Lch),RV411(Rch)
Playback Level (Deck A)
RV311
x
ao
u163
y
i
http://www.xiaoyu163.com
2 9
8
Record Level Adjustment (Deck B)
Procedure:
Press the p (CD) button while pressing the DIRECTION
1.
MODE button.
While pressing the p (CD) button, press the ª (TAPE A)
2.
button, set the function to "deck B".
3. Insert a tape into deck B, press the r REC button, and then
press the ( button to start recording.
4.
Mode: Record
AF OSC
5.
Mode: Playback
recorded
position
Q Q
3
6 7
1 3
1 5
6.
Confirm playback the signal recorded in step 2 become
adjustment level as follows.
If these levels do not adjustment level, adjust the RV301 (L-
CH) and RV351 (R-CH) on the MAIN board to repeat steps 3
and 4.
Adjustment level:
Output point from PFJ-1 playback level: 47.2 to 53.0 mV (–24.3 to
–23.3 dB)
Adjustment Location: MAIN board
[MAIN BOARD] (Component Side)
RV411
co
.
— 13 —
9 4
2 8
INPUT POINT
315Hz 50 mV (–23.8 dB)
600 Ω
attenuator
set
PFJ-1
PFJ-1
set
output
point
0 5
8
2 9
9 4
CNS102
Level (L ch)
RV351
CNS101
m
Record
Level (R ch)
9 9
blank tape
CS-123
level meter
2 8
9 9
RV301
Record
CNP105