Kenwood TK-7360 Service Manual page 39

Hide thumbs Also See for TK-7360:
Table of Contents

Advertisement

Item
Panel tuning mode
8. DQT
1) Adj item: [DQT]
Deviation
Adjust: [∗∗∗∗]
(Narrow)
2) TEST CH: Center
3) Deviation meter fi lter
LPF: 3kHz
HPF: OFF
4) PTT: ON
5) Press [
] key to
store the adjust-
ment value.
9. QT
1) Adj item: [QT]
Deviation
Adjust: [∗∗∗∗]
(Narrow)
2) TEST CH: Center
3) Deviation meter fi lter
LPF: 3kHz
HPF: OFF
4) PTT: ON
5) Press [
] key to
store the adjust-
ment value.
10. DTMF
1) Adj item: [DTMF]
Deviation
Adjust: [∗∗∗∗]
(Narrow)
2) TEST CH: Center
3) Deviation meter fi lter
LPF: 15kHz
HPF: OFF
4) PTT: ON
5) Press [
] key to
store the adjust-
ment value.
11. MSK
1) Adj item: [MSK]
Deviation
Adjust: [∗∗∗∗]
(Narrow)
2) TEST CH: Center
3) Deviation meter fi lter
LPF: 15kHz
HPF: OFF
4) PTT: ON
5) Press [
] key to
store the adjust-
ment value.
ADJUSTMENT
Condition
PC test mode
equipment
1) TEST CH: Center
Deviation
2) Deviation meter fi lter
meter
LPF: 3kHz
Oscillo-
HPF: OFF
scope
3) Transmit
AG
AF VTVM
1) TEST CH: Center
2) Deviation meter fi lter
LPF: 3kHz
HPF: OFF
3) Transmit
1) TEST CH: Center
2) Deviation meter fi lter
LPF: 15kHz
HPF: OFF
3) Transmit
1) TEST CH: Center
2) Deviation meter fi lter
LPF: 15kHz
HPF: OFF
3) Transmit
TK-7360/7360H/7360H
Measurement
Test-
Unit Terminal Unit
ANT
Adjustment
Specifi cations /
Parts
Method
[Panel
0.35kHz
±0.05kHz
tuning
mode]
[ ],[ ]
[PC test
mode]
FPU
0.35kHz
±0.05kHz
1.5kHz
±0.05kHz
1.5kHz
±0.05kHz
V
(
)
Remarks
39