Kenwood TK-7360 Service Manual page 38

Hide thumbs Also See for TK-7360:
Table of Contents

Advertisement

TK-7360/7360H/7360H
Item
Panel tuning mode
3. Mid Trans-
1) Adj item: [MPOW]
mit Power
Adjust: [∗∗∗∗]
2) TEST CH: Low,
TK-7360H/
Low', Center, High',
7360H(V)
High (5 points)
only
3) PTT: ON
4) Press [
] key to
store the adjust-
ment value.
4. Low Trans-
1) Adj item: [LPOW]
mit Power
Adjust: [∗∗∗∗]
2) TEST CH: Low,
Low', Center, High',
High (5 points)
3) PTT: ON
4) Press [
] key to
store the adjust-
ment value.
5. DQT
1) Adj item: [BAL]
Balance
Adjust: [∗∗]
(Narrow)
2) TEST CH: Low,
Low', Center, High',
High (5 points)
3) Deviation meter fi lter
LPF: 3kHz
HPF: OFF
4) PTT: ON
Output 20Hz
5) Press [ ] key during
PTT ON.
Output 1kHz
6) Press [
] key to
store the adjust-
ment value.
6. Maximum
1) Adj item: [DEV]
Deviation
Adjust: [∗∗∗∗]
(Narrow)
2) TEST CH: Low,
Low', Center, High',
High (5 points)
3) Deviation meter fi lter
LPF: 15kHz
HPF: OFF
4) PTT: ON
5) Press [
] key to
store the adjust-
ment value.
7. MIC
1) Adj item: [DEV]
Sensitivity
Adjust: [∗∗∗∗]
Check
2) TEST CH: Center
3) Deviation meter fi lter
LPF: 15kHz
HPF: OFF
AG: 1kHz/5mV
4) PTT: ON
38
V
(
)
ADJUSTMENT
Condition
PC test mode
equipment
1) TEST CH: Low,
Power
Low', Center, High',
meter
High (5 points)
Ammeter
2) Transmit
1) TEST CH: Low,
Low', Center, High',
High (5 points)
2) Transmit
1) TEST CH: Low,
Deviation
Low', Center, High',
meter
High (5 points)
2) Deviation meter fi lter
LPF: 3kHz
HPF: OFF
3) Transmit
1) TEST CH: Low,
Deviation
Low', Center, High',
meter
High (5 points)
Oscillo-
2) Deviation meter fi lter
scope
LPF: 15kHz
AG
HPF: OFF
AF VTVM
3) Transmit
1) TEST CH: Center
2) Deviation meter fi lter
LPF: 15kHz
HPF: OFF
AG: 1kHz/5mV
3) Transmit
Measurement
Test-
Unit Terminal Unit
ANT
ANT
ANT
ANT
MIC
Adjustment
Specifi cations /
Parts
Method
[Panel
25W
±1.0W
tuning
8.0A or less
mode]
[ ],[ ]
[PC test
mode]
FPU
5W
±0.5W
4.0A or less
The Deviation of
±0.4dB
20Hz frequency
is fi xed. (FL=30,
FLC=35, FC=40,
FCH=45, FH=50)
Change the 1kHz
adjustment value to
become the same
deviation of 20Hz
within the specifi ed
range.
2.2kHz
±0.05kHz
(According to the
large +, –)
Note:
FPU auto input
1kHz/50mV
Check
1.1kHz~1.8kHz
Remarks

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tk-7360hTk-7360h(v)

Table of Contents