Error Symptoms - IBM Netfinity 5100 8658 11Y Manual

Table of Contents

Advertisement

Error symptoms

Error Symptom
CD is not working
properly.
CD-ROM drive tray is
not working. (The
server must be
powered-on.)
CD-ROM drive is not
recognized.
Power switch does
not work and reset
button does work.
Diskette drive in-use
light stays on, or the
system bypasses the
diskette drive, or the
diskette drive does
not work.
FRU/Action
1. Clean the CD.
2. Run CD-ROM Diagnostic
3. CD-ROM Drive
1. Insert the end of a paper clip into
the manual tray-release opening.
2. Run CD-ROM Diagnostic
3. CD-ROM Drive
1. Run Configuration/Setup, enable
primary IDE channel.
2. Check cables and jumpers.
3. Check for correct device driver.
4. System Board
5. Run CD-ROM diagnostics
6. CD-ROM Drive
1. Verify that the power-on override
switch 5 of SW1 is set to Off (see
"System board switches and
jumpers" on page 57).
2. Power Switch Assembly
3. System Board
1. If there is a diskette in the drive,
verify that:
a. The diskette drive is enabled in
the Configuration/Setup utility
program.
b. The diskette is good and not
damaged. (Try another diskette
if you have one.)
c. The diskette is inserted correctly
in the drive.
d. The diskette contains the
necessary files to start the
server.
e. The software program is OK.
f. Cable is installed correctly
(proper orientation)
2. Run Diskette Drive Diagnostics.
3. Cable
4. Diskette Drive
5. System Board
Symptom-to-FRU index