Outdoor Unit (Ras-18Ua-E2); Outdoor Unit (Ras-18Uax2); Outdoor Unit (Ras-18Ua-Ar2) - Toshiba RAS-24UAH-E-1 Service Manual

Table of Contents

Advertisement

4-7. Outdoor Unit (RAS-18UA-E2)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5
Relay

4-8. Outdoor Unit (RAS-18UAX2)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5
Magnetic contactor

4-9. Outdoor Unit (RAS-18UA-AR2)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5
Magnetic contactor
Type
Output (Rated) 1500 W, 2 poles, 1 phase, 220 – 240 V, 50 Hz
PH250X3-4LM
Winding resistance (Ω)
(at 20°C)
Output (Rated) 42 W, 6 poles, 1 phase, 220 – 240 V, 50 Hz
HF-240-42B
Winding resistance (Ω)
(at 20°C)
451205KQ
AC 450 V, 2µF
371456JCR
AC 370 V, 45µF
VC20FA
220 – 240 V, 50 Hz, 1P1a
Type
Output (Rated) 1500 W, 2 poles, 1 phase, 220 – 240 V, 50 Hz
2JS350D5DA02
Winding resistance (Ω)
(at 20°C)
Output (Rated) 42 W, 6 poles, 1 phase, 220 – 240 V, 50 Hz
HF-240-42B-1
Winding resistance (Ω)
(at 20°C)
451205KQ
AC 450 V, 2µF
371456JCR
AC 370 V, 45µF
CLK-26J
220 – 240 V, 50 Hz
Type
Output (Rated) 1500 W, 2 poles, 1 phase, 220 – 240 V, 50 Hz
PH250X3-4LM
Winding resistance (Ω)
(at 20°C)
Output (Rated) 42 W, 6 poles, 1 phase, 220 – 240 V, 50 Hz
MMF-230-65A
Winding resistance (Ω)
(at 20°C)
451205KQ
AC 450 V, 2µF
SK42CMP45U1-S
AC 420 V, 45µF
A35
220 – 240 V, 50 Hz
– 21 –
FILE NO. SVM-03010(1)
Specifications
C-R
2.29
Red-Black
White-Black
176.2
Specifications
C-R
0.981
Red-Black
White-Black
176.2
Specifications
C-R
2.29
Red-Black
White-Black
71.25
C-S
1.22
290.5
C-S
2.845
290.5
C-S
1.22
139.0

Hide quick links: