5-3. RAS-24UKP-E-1 / RAS-24UA-E-1
RAS-24UKP-AR-1 / RAS-24UA-AR-1
Cooling
0.39 m
(Connecting pipe)
∅15.88
P
O.D.:15.88 mm
Packed valve
(∅15.88)
Gas container connection (Reinstall etc.)
Cooling
Cooling Compressor
Cooling
50 Hz
Standard
Cooling
High temperature
Low temperature
* SASO Standard's condition
Note : Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.)
Indoor unit
Evaporator
Cross flow fan
PH280X3-4MS
Accumulator
Condenser
Propeller fan
Outdoor unit
Standard
Surface temp. of heat
pressure P
exchanger interchanging
(MPaG)
0.4
0.7
0.3
– 25 –
FILE NO. SVM-03010(1)
T
Packed valve
(∅6.35)
Capillary tube
∅0.8x400 s
Capillary tube
∅2.4x1400 s
Refrigerant
R22 1.63 kg
Mark (
) means check points of Gas Leak
Fan speed
(indoor)
pipe T (°C)
11.0
High
12.0
High
1.0
Low
0.49 m
(Connecting pipe)
∅6.35
O.D.:6.35 mm
Ambient temp.
conditions DB/WB
(°C)
Indoor
Outdoor
27/19
35/24
32/23
52/31*
21/15
21/15

Hide quick links: