4-8. Outdoor Unit (RAS-24UA-AR3)
No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
Magnetic contactor
5
Type
Output (Rated) 2200 W, 2 poles, 1 phase, 220 − 240 V, 50 Hz
2JS386D5BB02
Winding resistance (Ω )
(at 20 °C)
Output (Rated) 65 W, 6 poles, 1 phase, 220 − 240 V, 50 Hz
Winding resistance (Ω )
MMF-230-65I
(at 20 °C)
AC 450 V, 3.5µF
451355KQ
AC 420 V, 60µF
SK42CMP60X1-S
220 − 240 V, 50 Hz
CLK-35J
– 21 –
FILE NO. SVM-04032
Specifications
C-R
0.886
Red-Black
71.2
C-S
1.979
White-Black
139.0