Install Part
Electric wiring connection
Take off handle on right side plate of outdoor unit (1 bolt).
Take off clamp, then connect and fix the power connect wire to wiring terminal
board.Wiring allocation should be in accordance with that of indoor unit.
Fix power connect wire by clamp.
Ensure that the wiring is done well.
Install handle (tightened by 1 bolt).
Wrong wiring connection will lead
to electric malfunction.
The lead between the joint and the fixed should
be a little free when fixing it with wire clamp.
Nut of connection pipe
Fig.7
Black
Brown
Blue
Wire clamp
Yellow-green