3. Replacement and Adjustment

Image Fusing

• Make sure that the fusing unit is cool before you touch it. The fusing unit can be very hot.
• Make sure to restore the insulators, shields, etc after you service the fusing unit.

Fusing Unit

3
1. Open the front cover.
2. Rear cover (* Rear Cover)
3. Right cover (* Right Cover)
4. Left cover (* Left Cover)
5. Disconnect the connectors [A] (hook) [B].
• The sponge [C] clamps the harness. Install this sponge in the same position after reinstalling the
fusing unit.