Extron electronics DTP CrossPoint 84 IPCP Setup Gudie page 16

Scaling presentation matrix switchers with dtp extension
Hide thumbs Also See for DTP CrossPoint 84 IPCP:
Table of Contents

Advertisement

Command
HDCP status
View input HDCP status
View HDCP status of all inputs
View output HDCP status
View HDCP status of all outputs
Input reports as an HDCP-authorized device
HDCP authorized device on
HDCP authorized device off
View HDCP authorized status
Execute Auto-Image
Execute Auto-Image
List Digital Sync Validation Processing (DSVP)
List sync of all inputs
Example:
X! = Input number
NOTE:
X@ = Output number
X$ = HDCP status (for inputs)
X% = HDCP status (for outputs)
X^ = HDCP authorized device
X& = TP (scaled) output number
X* = Signal detection status
Command
Input audio selection
Input audio selection
Example:
View input audio selection
View input audio all selections
Group master level (volume and mute)
NOTES:
The DTP CrossPoint 84 has 16 configurable group masters.
By factory default, group 1 controls the program volume and group 2 controls the mic volume.
Other group masters (such as mutes) must have been created in the DSP Configurator program to be available as
Set gain (+) or attenuation (−) dB
value
Example:
Increment dB value
Example:
Decrement dB value
View master value
Set mute or unmute
X!
NOTE:
= Input number
X#
= Mute
X(
= Input audio source
X1)
= Group number
X1!
= Group master value
SIS Command
Response
(Host to Unit)
(Unit to Host)
E
X!
}
X$]
I
HDCP
E
}
X$
X$
X$
I*HDCP
1
2
E
X@
}
X%]
O
HDCP
E
}
X%
X%
X%
O*HDCP
1
2
E
X!
}
X!
E
*1HDCP
HdcpE
E
X!
}
X!
E
*0HDCP
HdcpE
E
X!
}
X^]
E
HDCP
X&
X&]
*A
Img
X*
X*
X*
0LS
1
2
0LS
no input detected
Response Status:
01 – 08
01 – 04
0 = no source connected 1 = source is HDCP compliant 2 = source is not HDCP compliant
0 = No monitor connected
1 = Monitor connected but does not support HDCP
2 = Monitor connected, supports HDCP, but the video signal is not encrypted
7 = Monitor connected, supports HDCP, and the video signal is encrypted
0 = off
1 = on (default)
03 or 04
0 = no input connected
SIS Command
Response
(Host to Unit)
(Unit to Host)
E
X!
X(
}
X!
I
*
AFMT
AfmtI
E
}
I1*0AFMT
AfmtI1*0
E
X!
}
X(]
I
AFMT
E
}
X(
X(
X(
IAFMT
1
2
E
X1)
X1!
}
X1)
D
GRPM
GrpmD
E
}
D1*+50GRPM
GrpmD1*50
E
X1)
X1!
}
X1)
D
*
+GRPM
GrpmD
E
}
D1*75+GRPM
GrpmD1*125
E
X1)
X1!
}
X1)
D
*
−GRPM
GrpmD
E
X1)
}
X1!]
D
GRPM
E
X1)
X#
}
X1)
D
*
GRPM
GrpmD
01
08
0 = off (unmuted)
1 = on (muted)
0
= Auto (see the example above)
1
= HDMI (de-embedded digital audio) (default)
01 – 16 (can be a user-defined alias enclosed in brackets {})
dB value in 0.1 increments. Example: X1! = 50 = 5 dB.
Additional Description
X$
]
...
3
8
X%
]
3
4
]
Set the input as an HDCP authorized device.
*1
]
*0
Set the input as not an HDCP authorized device.
Show HDCP authorized device status.
X*
]
X*
...
3
8
Eight
s; each is the signal status of an input, starting from
input 1.
input detected
0 0 0 1 1 1 0 0
Input:
1 2 3 4 5 6 7 8
1 = input connected
Additional Description
X(]
*
]
Auto (0): Digital audio takes priority over analog audio.
X(
]
X(
...
3
8
Each
is the auto, analog, or HDMI selection of an audio
input, starting at input 1.
X1!]
Specify + for gain or - for attenuation.
*
]
Specify 5 dB level for group 1 (program volume).
X1!]
*
Increase master
]
Increase group 1 (program volume) by 7 . 5 dB (to 12 . 5 dB).
X1!]
*
Decrease master
X#]
*
Mute ( 1 ) or unmute ( 0 ) the group.
2
= Analog (local 2-channel audio)
X1)
s for SIS commands.
X1)
X1!
by
.
X1)
X1!
by
.

Advertisement

Table of Contents
loading