Dubbing only desired scenes
– Digital program editing
(4) Confirming the VCR operation
1 Insert a recordable tape into the VCR, then set
the VCR to recording pause.
2 Select IR TEST, then press EXEC.
3 Select EXECUTE, then press EXEC.
If the VCR starts recording, the setting is
correct.
The indicator you selected to cancel recording
pause on the VCR flashes on the LCD screen.
When finished, the indicator changes to
COMPLETE.
2,3
EXIT
OTHERS
OTHERS
ED I T SET
ED I T SET
CONTROL
CONTROL
ADJ TEST
ADJ TEST
"CUT - I N"
ENGAGE
"CUT - I N"
"CUT -OUT"
REC PAUSE
"CUT -OUT"
I R SETUP
I R SETUP
PAUSEMODE
RETURN
PAUSEMODE
EXECUTE
I R TEST
I R TEST
EXEC
RET.
When the VCR does not operate correctly
•After checking the code in "About the IR
SETUP" code, set the IR SETUP or the
PAUSEMODE again.
•Place your camcorder at least 30 cm (11 7/8 in.)
away from the VCR.
•Refer to the operating instructions of your VCR.
106
Dubbing only desired scenes
– Digital program editing
Step 3: Adjusting the
synchronicity of the VCR
You can adjust the synchronicity of your
camcorder and the VCR.
Prepare a pen and paper for notes.
Before operation, eject a cassette from your
camcorder.
(1) Set the POWER swtich to VCR (DCR-
PC9E)/PLAYER (DCR-PC6E) on your
camcorder.
(2) Insert a recordable tape into the VCR, then
set the VCR to recording pause.
When you select i.LINK in CONTROL, the
above procedure is not necessary.
(3) Select ADJ TEST, then press EXEC.
(4) Select EXECUTE, then press EXEC.
IN and OUT are recorded on an image for 5
times each to calculate the numerical values
for adjusting the synchronicity.
The "EXECUTING" indicator flashes on the
LCD screen. When finished, the indicator
changes to "COMPLETE".
(5) Rewind the tape in the VCR, then start slow
playback.
Take a note of the opening numerical value
of each IN and the closing numerical value
of each OUT.
(6) Calculate the average of all the opening
numerical values of each IN, and the
average of all the closing numerical values
of each OUT.
(7) Select "CUT-IN", then press EXEC.
(8) Select the average numerical value of IN,
then press EXEC.
The calculated start position for recording is
set.
(9) Select "CUT-OUT", then press EXEC.
(10) Select the average numerical value of OUT,
then press EXEC.
The calculated stop position for recording is
set.
(11) Select
RET. to execute.
108
1
2
3
EXIT
COMPLETE
EXEC
RET.
3
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
Dubbing only desired scenes
– Digital program editing
Step 2: Setting the VCR to
operate with the i.LINK cable
(DV connecting cable)
When you connect using the i.LINK cable (DV
connecting cable) (optional), follow the
procedures below.
(1) Set the POWER switch to VCR (DCR-PC9E)/
PLAYER (DCR-PC6E) on your camcorder.
(2) Turn the power of the connected VCR on,
then set the input selector to DV input.
When you connect a digital video camera
recorder, set its power switch to VCR/VTR.
(3) Press FN to display PAGE1.
(4) Press MENU, then select EDIT SET in
the menu settings, then press EXEC (p. 134).
(5) Select CONTROL, then press EXEC.
(6) Select i.LINK, then press EXEC.
4
EXIT
OTHERS
DATA CODE
BEEP
MELODY
COMMANDER
D I SPL AY
V I DEO ED I T
ED I T SET
EXEC
RET.
EXIT
OTHERS
ED I T SET
CONTROL
I R
ADJ TEST
"CUT - I N"
"CUT -OUT"
I R SETUP
PAUSEMODE
I R TEST
EXEC
RET.
Dubbing only desired scenes
– Digital program editing
3,4
EXIT
OTHERS
ED I T SET
CONTROL
ADJ TEST
RETURN
"CUT - I N"
EXECUTE
"CUT -OUT"
I R SETUP
PAUSEMODE
I R TEST
EXIT
OTHERS
ED I T SET
EXEC
RET.
CONTROL
ADJ TEST
EXECUT I NG
"CUT - I N"
"CUT -OUT"
No. 2
I R SETUP
I N
PAUSEMODE
+215
I R TEST
EXIT
OTHERS
ED I T SET
EXEC
RET.
CONTROL
ADJ TEST
COMPLETE
"CUT - I N"
"CUT -OUT"
I R SETUP
PAUSEMODE
I R TEST
EXEC
RET.
To return to FN
Press EXIT.
Notes
•When you complete step 3, the image to adjust
the syncronicity is recorded for about 50
seconds.
•If you start recording from the very beginning
of the tape, the first few seconds of the tape
may not be recorded properly. Be sure to allow
about 10 seconds' lead before starting the
recording.
•When the recording unit cannot be operated
properly by the i.LINK cable (DV connecting
cable), leave the connection as it is, and make
the A/V connecting cable settings (p. 102).
Video and audio are sent by digital signals.
1-25
2
(1)
(2)
in
(3)
(4)
(5)
(6)
3
FN
5,6
EXIT
EXIT
OTHERS
OTHERS
ED I T SET
ED I T SET
CONTROL
I R
CONTROL
I R
ADJ TEST
ADJ TEST
i. L I NK
"CUT - I N"
"CUT - I N"
"CUT -OUT"
"CUT -OUT"
I R SETUP
I R SETUP
PAUSEMODE
PAUSEMODE
I R TEST
I R TEST
EXEC
RET.
EXEC
RET.
OTHERS
EXIT
OTHERS
EXIT
ED I T SET
ED I T SET
CONTROL
I R
CONTROL
i. L I NK
ADJ TEST
i. L I NK
ADJ TEST
"CUT - I N"
"CUT - I N"
"CUT -OUT"
"CUT -OUT"
I R SETUP
I R SETUP
PAUSEMODE
PAUSEMODE
I R TEST
I R TEST
EXEC
RET.
EXEC
RET.
7,8
EXIT
EXIT
OTHERS
OTHERS
ED I T SET
ED I T SET
CONTROL
CONTROL
ADJ TEST
ADJ TEST
"CUT - I N"
0
"CUT - I N"
0
"CUT -OUT"
"CUT -OUT"
I R SETUP
I R SETUP
PAUSEMODE
PAUSEMODE
I R TEST
I R TEST
EXEC
RET.
EXEC
RET.
9,10
EXIT
EXIT
OTHERS
OTHERS
ED I T SET
ED I T SET
CONTROL
CONTROL
ADJ TEST
ADJ TEST
"CUT - I N"
"CUT - I N"
"CUT -OUT"
0
"CUT -OUT"
0
I R SETUP
I R SETUP
PAUSEMODE
PAUSEMODE
I R TEST
I R TEST
EXEC
RET.
EXEC
RET.
107
109

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcr-pc9eDcr-pc9

Table of Contents