Sony DCR-PC6E Service Manual page 33

Hide thumbs Also See for DCR-PC6E:
Table of Contents

Advertisement

Dubbing only desired scenes
– Digital program editing
Notes
•You cannot dub the titles, display indicators, or
the contents of cassette memory.
•When you connect with an i.LINK cable (DV
connecting cable), you may not be able to
operate the dubbing function correctly,
depending on the VCR.
Set CONTROL to IR in the menu settings of
your camcorder .
•When editing digital video, the operation
signals cannot be sent with LANC
.
Step 1: Connecting the VCR
You can connect either the A/V connecting cable
or the i.LINK cable (DV connecting cable).
When you use the A/V connecting cable, connect
the devices as illustrated in page 97. When you
use the i.LINK cable (DV connecting cable),
connect the devices as illustrated in page 99.
If you connect using an i.LINK cable (DV
connecting cable)
With digital-to-digital connection, video and
audio signals are transmitted in digital form for
high-quality editing.
Step 2: Setting the VCR to
operate with the A/V
connecting cable
To edit using the VCR, send the control signal by
infrared rays to the remote sensor on the VCR.
When you connect using the A/V connecting
cable, follow the procedures below, (1) to (4), to
send the control signal correctly.
102
Dubbing only desired scenes
– Digital program editing
About the IR SETUP code
The IR SETUP code is stored in the memory of
your camcorder. Be sure to set the correct code,
depending on your VCR. Default setting is code
number 3.
Brand/
IR SETUP code/
Sony
1, 2, 3, 4, 5, 6
Aiwa
47, 53, 54
Akai
50, 62, 74
Alba
73
Aristona
84
Baird
30, 36
Blaupunkt
78, 83
Bush
74
Canon
97
CGM
36, 47, 83
Clatronic
73
Daewoo
26
Ferguson
76
Fisher
73
Funai
80
Goldstar
47
Goodmans
26, 84
Grundig
9, 83
Hitachi
42, 56
ITT/Nokia Instant
36
JVC
11, 12, 15, 21
Kendo
47
Loewe
16, 47, 84
Luxor
89
Mark
26
*
Matsui
47, 58
*
, 60
* TV/VCR component/
Note on the IR SETUP code
Digital program editing is not possible if the VCR
does not support IR SETUP codes.
104
1
2
Brand/
IR SETUP code/
Mitsubishi
28, 29
Nokia
36, 89
Nokia Oceanic
89
Nordmende
76
Okano
60, 62, 63
Orion
58
*
, 70
Panasonic
16, 78, 96
Philips
83, 84, 86
Phonola
83, 84
Roadstar
47
SABA
21, 76
Samsung
22, 52, 93, 94
Sanyo
36
Schneider
10, 84
SEG
73
Seleco
47, 74
Sharp
89
Siemens
10, 36
Tandberg
26
Telefunken
91, 92
Tensai
73
Thomson
76, 100
Thorn
36, 47
Toshiba
40
Universum
47, 70, 92
W.W. House
47
Watoson
58, 83
Dubbing only desired scenes
– Digital program editing
(1) Setting the IR SETUP code
1 Set the POWER switch to VCR (DCR-PC9E)/
PLAYER (DCR-PC6E) on your camcorder.
2 Turn the power of the connected VCR on,
then set the input selector to LINE.
When you connect a video camera recorder,
set its power switch to VCR/VTR.
3 Press FN to display PAGE1.
4 Press MENU, then select EDIT SET in
the menu settings (p. 134).
Then press EXEC.
5 Select CONTROL, then press EXEC.
6 Select IR, then press EXEC.
7 Select IR SETUP, then press EXEC.
8 Select the IR SETUP code of your VCR, then
press EXEC. See the following page about the
IR SETUP code.
4
OTHERS
EXIT
DATA CODE
BEEP
COMMANDER
D I SPL AY
V I DEO ED I T
ED I T SET
IR
RET.
EXEC
5
EXIT
OTHERS
ED I T SET
CONTROL
I R
ADJ TEST
"CUT - I N"
"CUT -OUT"
I R SETUP
PAUSEMODE
I R TEST
EXEC
RET.
Dubbing only desired scenes
– Digital program editing
(2) Setting the modes to cancel the
recording pause on the VCR
1 Select PAUSEMODE, then press EXEC.
2 Select the mode to cancel recording pause on
the VCR, then press EXEC.
The correct button depends on your VCR.
Refer to the operating instructions of your
VCR.
1
2
EXIT
OTHERS
ED I T SET
CONTROL
ADJ TEST
"CUT - I N"
"CUT -OUT"
I R SETUP
PAUSE
REC
PAUSEMODE
I R TEST
PB
EXEC
RET.
The buttons canceling recording pause on the
VCR
The buttons vary depending on your VCR. To
cancel recording pause of your VCR:
– Select "PAUSE" if the button to cancel
recording pause is X.
– Select "REC" if the button to cancel recording
pause is z.
– Select "PB" if the button to cancel recording
pause is N.
(3) Locate the infrared rays emitter
of your camcorder and face it
towards the remote sensor of the
VCR
Set the devices about 30 cm (11 7/8 in.) apart,
and remove any obstacles between the devices.
Infrared rays emitter/
A/V connecting cable/
1-24
1
2
in
3
4
5
6
7
8
3
FN
6~8
EXIT
OTHERS
OTHERS
ED I T SET
ED I T SET
CONTROL
I R
CONTROL
I R
ADJ TEST
i. L I NK
ADJ TEST
"CUT - I N"
"CUT - I N"
"CUT -OUT"
"CUT -OUT"
I R SETUP
I R SETUP
PAUSEMODE
PAUSEMODE
I R TEST
I R TEST
EXEC
RET.
EXEC
EXIT
OTHERS
OTHERS
ED I T SET
ED I T SET
CONTROL
CONTROL
ADJ TEST
ADJ TEST
"CUT - I N"
"CUT - I N"
"CUT -OUT"
"CUT -OUT"
I R SETUP
3
I R SETUP
1
PAUSEMODE
PAUSEMODE
I R TEST
I R TEST
EXEC
RET.
EXEC
1
2
EXIT
OTHERS
ED I T SET
CONTROL
ADJ TEST
"CUT - I N"
"CUT -OUT"
I R SETUP
PAUSE
PAUSEMODE
I R TEST
EXEC
RET.
X
z
N
VCR/
Remote sensor/
EXIT
RET.
EXIT
RET.
103
105

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcr-pc9eDcr-pc9

Table of Contents