Center Of Gravity; Clearances - York Champion Series Technical Manual

Single package heat pumps
Hide thumbs Also See for Champion Series:
Table of Contents

Advertisement

036-21311-003-A-0104

CENTER OF GRAVITY

FRONT
OF
A
UNIT
B
25
"'

&

CLEARANCES

UNIT CLEARANCES
(Minimum)
Front
12"
Back
0"
Left Side (Filter Access) 24"
Right Side
24"
1
Below Unit
0"
36" (For Condenser
2
Above Unit
1
Units may be installed on combustible floors made from wood or class A,
B or C roof covering material.
2
Units must be installed outdoors. Overhanging structures or shrubs
should not obstruct outdoor air discharge outlet.
NOTE: FOR UNITS APPLIED WITH A ROOF CURB, THE
MINIMUM CLEARANCE MAY BE REDUCED FROM 1
INCH TO 1/2 INCH BETWEEN COMBUSTIBLE ROOF
CURB MATERIAL AND THE SUPPLY DUCT.
Unitary Products Group
CENTER OF GRAVITY
D
C
"%
22

"
Air Discharge)
FLEXIBLE DUCT
COLLAR
BHA
SHIPPING
OPERATING
UNIT
WEIGHT
WEIGHT
SIZE
018
350
024
350
030
360
036
367
042
394
048
445
060
490
MINIMUM CLEARANCE OF 1"
ALL SIDES FOR THE FIRST 3'
OF DUCT FOR 20 & 25 kW.
ZERO INCHES THEREAFTER,
FOR ALL OTHER HEATERS,
ZERO INCH CLEARANCE ALL
SIDES FOR ENTIRE LENGTH
OF DUCT.
3'
CORNER WEIGHTS
A
B
C
D
345
103
92
73
82
345
95
92
80
83
355
98
94
82
85
362
100
96
84
87
389
107 103
90
93
440
121
117
102 105
485
133 129
112
116
21