Installation Of Vitotronic Control - Viessmann VITOROND 100 Installation And Service Instructions Manual

Oil-fired
Table of Contents

Advertisement

Burner Set-up (Beckett)
Electrical connections (with Vitotronic control) (continued)

Installation of Vitotronic control

1.
Fig. 33
(continued)
2.
2.
4.
3.
Room thermostat wiring
1. Install thermostat on inside wall
2. Follow instructions supplied with
The power supply cable is shipped with
the boiler control.
5.
Boiler temperature sensor
with the boiler control (not applicable to
Vitotronic 100, KK10).
Connections
away from influences of drafts, hot
or cold water pipes, lighting fixtures,
television, sun rays or fireplaces.
room thermostat. If it has a heat
anticipator, set heat anticipator in
thermostat to match power
requirements of equipment connected
to it. Boiler wiring diagrams give
setting for standard equipment.
Installation Instructions
Boiler Control (for all
connections to control base)
IMPORTANT
1. Loosen two screws and remove
cover plate.
2. Remove top back panel.
3. Remove front panel.
4. Place control console on boiler and
fasten with two screws removed in
step 1.
WARNING
Do not kink capillaries. Proper
operation of sensors is not possible if
capillaries are kinked.
IMPORTANT
5. Carefully push high limit and boiler
temperature sensor
panel and into sensor wells as far as
possible. Lay excess sensor cabling
and capillary tubing on insulation.
is shipped
behind front
37