SET UP MENU

Many additional parameters can be modified via the
Set Up Menu. To access the Set Up Menu:
• Position the ON/OFF switch to OFF "0".
• Depress and hold the Parameter select Push Button.
• Position the On/Off switch to on "I" at the back of
the machine; the input voltage light "Item 1" (green
LED) confirms normal operation.
• The Digital display "Item 1" will show the figure 0,
the SETUP mode is confirmed by a center "0" on
the Digital display
- Rotate the Output / Parameter Adjust Knob,
the Digital Display shows the numbers corre-
sponding to the parameters in sequence;
stop at the desired parameter and push the
"Setup/Parameter Push Button".
-With parameter (9) all the modifications made
in the SETUP mode are cancelled and the
standard values set by Invertec V205-T
AC/DC are restored.
Indicator
0
Exit From Set Up
1
Setting the initial "I" percentage on the welding "I"(2 – 200%)
2
Pre Flow Time (0-25s)
3
Arc Force, Percent above Peak Current for Stick only (0 – 100%)
4
Hot Start, Percent above Peak Current for Stick only (0 – 100%)
5
Setting the AC Wave Form
6
Min Current Value with Remote Control (6 Amps – Peak Current)
7
Max Current Value with Remote Control (6 Amps – Peak Current)
8
Touch Start or HF Start in DC, Ignored in AC 0 = HF, 1 = Touch Start
9
Reset of all Parameters
10
Not Used
11
Not Used
12
2 Step Trigger Selection
13
4 Step Trigger Selection
14
OPERATION
Parameter
0 = Sinusoidal
(+ and -)
1 = Triangular
(+ and -)
2 = Square
(+ and - )
0 = Restart Disabled
1 = Restart Enabled
0 = Restart Disabled
1 = Restart Enabled
Start Power, for TIG only
This function increases the initial Start Current.
(1 = min., 5 = max.)
V205-T AC/DC TIG
- The number on the Digital display "Item 6" is
replaced by the value of the parameter that
can be modified through the potentiometer
"Item 5".
- To exit the Set Up Menu, return to "0" and
press the Setup/Parameter Push Button
B-6
Default
50%
0.5s
30%
80%
2 (Square)
6 Amps
Peak Current
0
1
0
1