Maintenance

Replacing the lamp

A lamp has finite product life. Using the lamp for long periods of time could cause the
pictures darker or the color tone poor. Note that each lamp has a different lifetime, and
some may burst or burn out soon after you start using them.
Preparation of a new lamp and early replacement are recommended. To prepare a
new lamp, make contact with your dealer and tell the lamp type number.
Type number <8970, 8972W, 8974WU>: 456-8970
Type number <8971, 8973W, 8975WU, 8976SX>: 456-8971
Replacing the lamp
1.
Turn the projector off, and unplug the power cord. Allow
the projector to cool for at least 45 minutes.
2.
Prepare a new lamp. If the projector is mounted with
specified mounting accessories, or if the lamp has broken,
also ask the dealer to replace the lamp.
In case of replacement by yourself, follow the following
procedure.
3.
Loosen the screw (marked by arrow) of the lamp cover and then
slide down and lift the lamp cover to remove it.
4.
Loosen the 3 screws (marked by arrow) of the
lamp, and slowly pull the lamp out by the handles.
Never loosen any other screws.
5.
Insert the new lamp, and retighten firmly the 3
screws of the lamp that are loosened in the previous
process to lock it in place.
6.
While putting the interlocking parts of the lamp cover and
the projector together, slide the lamp cover back in place.
Then firmly fasten the screw of the lamp cover.
7.
Turn the projector on and reset the lamp time using the LAMP
TIME item in the OPTION menu.
(1) Press the MENU button to display a menu.
(2) Point at the ADVANCED MENU in the menu using the ▼/▲
button, then press the ► button.
(3) Point at the OPTION in the left column of the menu using the
▼/▲button, then press the ► button.
(4) Point at the LAMP TIME using the ▼/▲ button, then press the ► button. A dialog will appear.
(5) Press the ► button to select "OK" on the dialog. It performs resetting the lamp time.
CAUTION
taken out.
NOTE
• Please reset the lamp time only when you have replaced the lamp,
for a suitable indication about the lamp.
►Do not touch the interior of the projector, while the lamp is
Maintenance
3
Lamp cover
Handles
4, 5
6
111