10. Initialization to factory settings

Caution: When initialization is performed, all user setting data including the channel settings are initial-
ized. Be cautious when making this adjustment.
(The adjustments done in the adjustment process mode are not initialized.)
Adjustment item
1
Initialization
After the adjustment, cancel the adjustment process mode.
To exit the adjustment process mode, unplug the AC power cable from the outlet to make a forced
shutdown. (When the power was turned off with the remote controller, once unplug the power cable
and plug it again. In this case, wait 10 seconds or so before plugging.)
Adjustment conditions
Enter the adjustment process mode.
It turns off with AC pow-
Bring the cursor on to [INDUSTRY INIT] in page 2/29.
er supply.
Set to [ON] using [VOL] key, and press [ENTER] to execute the
initialization.
When the initialization is complete, the adjustment process mode screen is
automatically replaced by the TV's 1ch screen.
* Never shut off the power during the initialization process.
The following settings are initialized in this adjustment.
1. User setting
2. Channel data (e.g. broadcast frequencies)
3. Password data
4. Operation time
5. Maker's optional setting
6. Auto installation flag
7. V-CHIP block setting
Adjustment procedure